首页> 美国卫生研究院文献>Journal of Cardiovascular and Thoracic Research >Intra-aortic balloon pump experience: a single center study comparing with and without sheath insertion
【2h】

Intra-aortic balloon pump experience: a single center study comparing with and without sheath insertion

机译:主动脉内球囊泵经验:单中心研究比较有无鞘套插入

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Introduction: The mechanical circulation support used in treatment of low cardiac output at most is the intra-aortic balloon pump (IABP). Its usage fields are the complications occurring due to ischemic heart disease, disrupted left ventricle function, and the low cardiac output syndrome occurring during coronary artery by-pass surgery. >Methods: During 28 years from 1985 to 2013, IABP support has been implemented to 3135 patients in our cardiac surgery operating theater and intensive care unit. The mean age of the patients was 61.4 ± 13.2 years (16-82). 2506 patients (80%) were the ones whom the cardiac surgery has been implemented. IABP support has been provided for 629 (20%) patients for medical treatment. We utilized IABP most frequently in coronary artery patients (70%). The first choice for placing the balloon catheter is the femoral artery in 3093 cases (98.7%). >Results: The most frequently observed balloon complication was the lower extremity ischemia in 383 cases (12.2%).The leg ischemia was statistically significantly more frequent in patients with sheath (P=0.004). The extremity ischemia has developed in 4 of 12 patients with balloon placed from upper extremity. The local bleeding and balloon rupture were more frequent in patientswhom the balloon has been placed without sheath. The mortality due to IABP has occurred inonly 5 patients.>Conclusion: Despite increase in IABP usage frequency rapidly, the complications due to catheterare still seen. We believe that the leg ischemia that is the most frequently seen complication canbe prevented via IABP use without sheath.
机译:>简介:最多可用于治疗低心输出量的机械循环支持是主动脉内球囊泵(IABP)。它的使用领域是由于缺血性心脏病引起的并发症,左心室功能受损以及在冠状动脉旁路手术期间发生的低心输出量综合征。 >方法:从1985年到2013年的28年中,我们的心脏外科手术室和重症监护室已为3135名患者实施了IABP支持。患者的平均年龄为61.4±13.2岁(16-82)。已实施心脏手术的患者为2506名患者(80%)。 IABP已为629名(20%)患者提供了医疗支持。我们最常在冠状动脉患者中使用IABP(70%)。放置球囊导管的首选是3093例(98.7%)的股动脉。 >结果:最常见的球囊并发症是383例下肢缺血(12.2%)。在鞘膜炎患者中,腿部缺血的发生率有统计学意义(P = 0.004)。在上肢放置气球的12例患者中,有4例发生了肢端缺血。患者局部出血和球囊破裂更常见放置气球的人没有鞘。 IABP造成的死亡发生在只有5位患者。>结论:尽管IABP使用频率迅速增加,但由于导管引起的并发症仍然被看到。我们认为,最常见的并发症是腿部缺血可以通过IABP不用护套来预防。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号