首页> 美国卫生研究院文献>PeerJ Computer Science >Optimization of the image acquisition procedure in low-field MRI for non-destructive analysis of loin using predictive models
【2h】

Optimization of the image acquisition procedure in low-field MRI for non-destructive analysis of loin using predictive models

机译:使用预测模型对低场MRI的图像采集过程的优化

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The use of low-field magnetic resonance imaging (LF-MRI) scanners has increased in recent years. The low economic cost in comparison to high-field (HF-MRI) scanners and the ease of maintenance make this type of scanner the best choice for nonmedical purposes. However, LF-MRI scanners produce low-quality images, which encourages the identification of optimization procedures to generate the best possible images. In this paper, optimization of the image acquisition procedure for an LF-MRI scanner is presented, and predictive models are developed. The MRI acquisition procedure was optimized to determine the physicochemical characteristics of pork loin in a nondestructive way using MRI, feature extraction algorithms and data processing methods. The most critical parameters (relaxation times, repetition time, and echo time) of the LF-MRI scanner were optimized, presenting a procedure that could be easily reproduced in other environments or for other purposes. In addition, two feature extraction algorithms (gray level co-occurrence matrix (GLCM) and one point fractal texture algorithm (OPFTA)) were evaluated. The optimization procedure was validated by using several evaluation metrics, achieving reliable and accurate results (r > 0.85; weighted absolute percentage error (WAPE) lower than 0.1%; root mean square error of prediction (RMSEP) lower than 0.1%; true standard deviation (TSTD) lower than 2; and mean absolute error (MAE) lower than 2). These results support the high degree of feasibility and accuracy of the optimized procedure of LF-MRI acquisition. No other papers present a procedure to optimize the image acquisition process in LF-MRI. Eventually, the optimization procedure could be applied to other LF-MRI systems.
机译:近年来,使用低场磁共振成像(LF-MRI)扫描仪增加。与高场(HF-MRI)扫描仪相比的经济成本低,易于维护使这种类型的扫描仪成为非医疗目的的最佳选择。然而,LF-MRI扫描仪产生低质量的图像,鼓励识别优化程序以产生最佳图像。在本文中,提出了LF-MRI扫描仪的图像采集过程的优化,并且开发了预测模型。 MRI采集程序经过优化,以使用MRI,特征提取算法和数据处理方法以非破坏性方式确定猪肉腰部的物理化学特征。优化LF-MRI扫描仪的最关键参数(放松时间,重复时间和回波时间),呈现可以在其他环境中容易地再现的过程或用于其他目的。另外,评估了两个特征提取算法(灰度共发生矩阵(GLCM)和一个点分形纹理算法(OPFTA))。通过使用多种评估度量来验证优化程序,实现可靠和准确的结果(R> 0.85;加权绝对百分比误差(WAPE)低于0.1%;预测的根均方误差(RmSEP)低于0.1%;真正的标准偏差(TSTD)低于2;并且平均误差(MAE)低于2)。这些结果支持LF-MRI采集优化程序的高度可行性和准确性。没有其他论文提出了优化LF-MRI中的图像采集过程的过程。最终,优化过程可以应用于其他LF-MRI系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号