Preloading Coil in Plug Method (p-CIP) with the AVP 2 for large Portosystemic Shunt Embolization

机译:具有插头法(P-CIP)的预加载线圈具有AVP 2用于大型PortoSystemic分流栓塞

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Hepatic encephalopathy caused by a large portosystemic shunt (PSS) can be treated by endovascular embolization of the shunt. The PSS diameter can be >20 mm; it occasionally poses technical difficulties. Here, a 72-year-old woman with liver cirrhosis, hyperammonemia, and large spleno-renal shunt underwent shunt embolization using an Amplatzer vascular plug 2 (AVP2) and metallic coils. The preloading coil in plug method (p-CIP), which facilitated embolization inside the AVP2 without cannulation from outside, was employed to overcome technical difficulties. We propose the use of p-CIP with an AVP2 as a tool for treatment of hepatic encephalopathy with PSS.
机译:由大型托管系统分流(PSS)引起的肝脑病可以通过分流器的血管栓塞治疗。 PSS直径可以> 20毫米;它偶尔会带来技术困难。在这里,一名72岁的女性肝硬化,高血肿性和大型脾脏肾分流器使用放大器血管插头2(AVP2)和金属线圈进行分流栓塞。采用插头方法(P-CIP)中的预加载线圈,其促进了AVP2内没有外部插管的栓塞,以克服技术困难。我们建议使用P-CIP与AVP2作为治疗PSS肝癌的工具。