首页> 美国卫生研究院文献>Journal of Clinical and Diagnostic Research : JCDR >Comparative Evaluation of Microleakage of Lingual Retainer Wires Bonded with Three Different Lingual Retainer Composites: An In Vitro Study
【2h】

Comparative Evaluation of Microleakage of Lingual Retainer Wires Bonded with Three Different Lingual Retainer Composites: An In Vitro Study

机译:三种不同的舌形保持架复合材料粘结的舌形保持架钢丝微渗漏的比较评估:一项体外研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Objective: To evaluate microleakage when two types of retainer wires were bonded with two light cured and a self cured lingual retainer composites.>Materials and Methods: Total 120 freshly extracted human mandibular incisor teeth were collected and separated into six subgroups of 20 teeth each. Two different wires, a 0.036 inch hard round stainless steel (HRSS) wire sandblasted at the ends and 0.0175 inch multistranded wire bonded onto the lingual surfaces of the incisors with three different types of composite resins of 3M company; Concise Orthodontic (self-cure), Transbond XT (light-cure) and Transbond LR (light-cure). Specimens were further sealed with a nail varnish, stained with 0.5% basic fuchsine for 24 hours, sectioned and examined under a stereomicroscope, and scored for microleakage for the enamel-composite and wire-composite interfaces. Statistical analysis was performed by Kruskal-Wallis and Mann-Whitney U-tests.>Results: For HRSS wire, at the enamel-composite interface, the microleakage was least with Transbond LR followed by Concise Orthodontic and greatest for Transbond XT (p<0.05). At the wire composite interface too, the microleakage was in order of Transbond LR<Concise Orthodontic<Transbond XT. For the multistranded wire, at the enamel-composite interface, the microleakage was least with Transbond LR followed by Concise Orthodontic and Transbond XT (p<0.05). At the wire composite interface too, it was seen that microleakage was the least with Transbond LR followed by Concise Orthodontic and Transbond XT.>Conclusion: Transbond LR in combination with 0.0175 inch multistranded wire showed least microleakage amongst the groups studied.
机译:>目的:用于评估两种类型的固定线与两种光固化和自固化的舌状固定器复合材料粘结时的微渗漏。>材料和方法:总共120颗新鲜提取的人类下颌切牙收集牙齿并将其分为六个亚组,每组20个牙齿。两种不同的金属丝,一种是在末端进行喷砂处理的0.036英寸硬质圆形不锈钢(HRSS)钢丝,另一种是用3M公司的三种不同类型的复合树脂粘结在门牙舌面上的0.0175英寸多股钢丝;简洁的正畸(自固化),Transbond XT(光固化)和Transbond LR(光固化)。样品用指甲油进一步密封,用0.5%碱性品红染色24小时,切片并在立体显微镜下检查,并对搪瓷复合材料和金属复合材料的界面进行微渗漏评分。统计分析是通过Kruskal-Wallis和Mann-Whitney U检验进行的。>结果:对于HRSS焊丝,在搪瓷-复合材料界面,Transbond LR的微渗漏最少,其次是简正畸形,最大的渗漏为Transbond XT(p <0.05)。在金属丝复合材料界面处,微渗漏的顺序也依次为Transbond LR <简明正畸结论: Transbond LR与0.0175英寸多股导线的组合中,微渗漏最少。研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号