首页> 美国卫生研究院文献>Sensors (Basel Switzerland) >Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode
【2h】

Electrochemical Detection of C-Reactive Protein in Human Serum Based on Self-Assembled Monolayer-Modified Interdigitated Wave-Shaped Electrode

机译:基于自组装单层改性的互化波形电极的人血清中C反应蛋白的电化学检测

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

An electrochemical capacitance immunosensor based on an interdigitated wave-shaped micro electrode array (IDWµE) for direct and label-free detection of C-reactive protein (CRP) was reported. A self-assembled monolayer (SAM) of dithiobis (succinimidyl propionate) (DTSP) was used to modify the electrode array for antibody immobilization. The SAM functionalized electrode array was characterized morphologically by atomic force microscopy (AFM) and energy dispersive X-ray spectroscopy (EDX). The nature of gold-sulfur interactions on SAM-treated electrode array was probed by X-ray photoelectron spectroscopy (XPS). The covalent linking of anti-CRP-antibodies onto the SAM modified electrode array was characterized morphologically through AFM, and electrochemically through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The application of phosphate-buffered saline (PBS) and human serum (HS) samples containing different concentrations of CRP in the electrode array caused changes in the electrode interfacial capacitance upon CRP binding. CRP concentrations in PBS and HS were determined quantitatively by measuring the change in capacitance (ΔC) through EIS. The electrode immobilized with anti-CRP-antibodies showed an increase in ΔC with the addition of CRP concentrations over a range of 0.01–10,000 ng mL−1. The electrode showed detection limits of 0.025 ng mL−1 and 0.23 ng mL−1 (S/N = 3) in PBS and HS, respectively. The biosensor showed a good reproducibility (relative standard deviation (RSD), 1.70%), repeatability (RSD, 1.95%), and adequate selectivity in presence of interferents towards CRP detection. The sensor also exhibited a significant storage stability of 2 weeks at 4 °C in 1× PBS.
机译:报道基于叉指状波浪形微电极阵列(IDWμE)用于直接和无标记检测C-反应蛋白(CRP)的上的电化学电容免疫传感器。一种自组装单层硫代双(SAM)(琥珀酰亚胺丙酸酯)(DTSP)用于修改抗体固定电极阵列。所述SAM官能电极阵列用原子力显微镜(AFM)和能量色散X射线光谱(EDX)形态学特征。金 - 硫相互作用的SAM处理的电极阵列上的性质,通过X射线光电子能谱(XPS)进行探测。抗CRP抗体到SAM的连接的共价修饰电极阵列形态学特征通过AFM,并通过电化学循环伏安法(CV)和电化学阻抗谱(EIS)。磷酸盐缓冲盐水(PBS)和含有在后CRP结合电极界面电容电极阵列所引起的变化不同浓度的CRP的人血清(HS)的样品中的应用。在PBS和HS CRP浓度通过测量通过EIS在电容(ΔC)的变化定量。固定有抗CRP抗体的电极显示出与添加CRP浓度在一定范围的0.01-10,000纳克ML-1的增加ΔC。 0.025的电极显示出检测限纳克ML-1和0.23纳克ML-1(S / N = 3)在PBS中,HS,分别。生物传感器显示出了良好的再现性(相对标准偏差(RSD),1.70%),重复性(RSD,1.95%),和足够的选择性在朝向CRP检测干扰物存在。该传感器还于4℃在1×PBS中表现出2周一个显著储存稳定性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号