首页> 美国卫生研究院文献>Journal of Animal Science >PSIV-11 Description of a novel Calorimetric unit to determine net energy in group housed pigs
【2h】

PSIV-11 Description of a novel Calorimetric unit to determine net energy in group housed pigs

机译:PSIV-11对新型量油装置的描述以确定群体猪的净能量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The Swine Calorimeter Unit (SCU) is being developed at the University of Illinois at Urbana-Champaign. The objective of the SCU unit is to be able to determine net energy (NE) of diets and ingredients fed on an ad-libitum basis to group-housed pigs in all phases of production. The SCU allows for calculating NE based on the indirect calorimetry procedure. There are 6 calorimetry chambers in the SCU. Each chamber is made air-tight by means of a gasketed surface, measures 1.8 × 2.1 × 2.7 m, has fully slatted floors, and a volume of 10.2 m3, with capacity to hold 4 to 10 growing-finishing pigs depending on size. There are manure screens and urine pans under the slatted floors. Each chamber is equipped with a fresh air supply system (Fantech, Lenexa, KS, and Accutrol LLC, Monroe, CT). Humidity and temperature in each chamber is controlled by a regulator unit (Parameter, Black Mountain, NC). The precision for maintenance of the temperature can be controlled with an accuracy of ± 0.1°C and relative humidity (RH) ±0.5%. These levels of precision are ensured by the use of a dew point control system. To measure the gas exchange in the chambers, the Classic Line system developed by Sable Systems International is used (Sable System International, North Las Vegas, NV). The air subsample first enters the methane analyzer, then the CO2 analyzer, and as the last step the oxygen analyzer. The gas analyzers provide readings in percentage units with high resolution (0.00001 to 0.01%) depending on gas concentrations. Those values are obtained in a determined period of time to be able to calculate total heat production from each chamber. Operation of the SCU will start in January 2019, and the initial objectives include comparisons of net energy in individually housed and group housed pigs.
机译:猪热量计单位(SCU)正在伊利诺伊州厄巴纳·香槟大学开发。 SCU单位的目的是能够确定饮食和成分的净能量(NE),并在所有阶段对群体饲养的猪进行饲喂。 SCU允许基于间接量热法过程计算NE。 SCU中有6个热量腔室。每个腔室通过垫圈的表面空气密封,措施1.8×2.1×2.7米,具有完全速度的地板,体积为10.2平方米,容量根据尺寸保持4至10个生长的猪。在板条楼层下有粪便和尿粉丝。每个腔室都配备了新的空气供应系统(Fantech,Lenexa,Ks和Accutrol LLC,Monroe,CT)。每个腔室中的湿度和温度由调节装置(参数,黑山,NC)控制。可以控制维护温度的精度,精度为±0.1°C和相对湿度(RH)±0.5%。通过使用露点控制系统确保了这些精度等级。为了测量腔室中的气体交换,使用了由Sable Systems International开发的经典线系(Sable System International,North Las Vegas,NV)。空气子样本首先进入甲烷分析仪,然后进入二氧化碳分析仪,作为氧气分析仪的最后一步。气体分析仪根据气体浓度为具有高分辨率高(0.00001至0.01%)的百分比单位的读数。这些值是在确定的时间段中获得的,以能够从每个腔室计算总热量。 SCU的运作将于2019年1月开始,最初的目标包括单独容纳的净能量的比较和群体的猪。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号