Standardized uptake values (SUVs) of 18F-fluorodeoxyglucose positron emission tomography (FDG PET) are widely used to help characterize pulmonary nodules. The purpose of this study is to assess the accuracy of the SUV corrected by blood glucose levels (SUVgluc), compared to four other commonly used semi-quantitative methods: maximal SUV normalized to body weight (SUVmax), ratio of SUV of nodule to cerebellum (SUVcer), SUV normalized to body surface area (SUVbsa) and SUV normalized to body mass index (SUVbmi). 52 patients with lung nodules had FDG PET scans, consecutively imaged between 7/1/2015 and 6/7/2016. Histopathologic result of the nodules, obtained within two months after the FDG PET scan, demonstrated 10 benign and 42 malignant lung nodules. The SUVgluc was defined as SUVmax × blood glucose level/100. The average SUVmax was 2.8 for benign nodules and 7.7 for malignant nodules. No significant difference in the receiver operating characteristic (ROC) area under the curves (AUCs) were found between the SUVmax (0.84) and the SUVcer (0.87) or SUVbsa (0.86), or SUVbmi (0.86) with p-values greater than 0.05; however, the ROC AUC for the SUVgluc (0.90) was larger than that for the SUVmax with p-value of 0.03. These results suggest that SUVgluc may assist in more accurately representing the glucose metabolism of malignant lung nodules by accounting for the patient’s blood glucose level (BGL). The simplicity of the SUVgluc method avoids an additional reference ROI, uses preexisting clinical data, i.e. pre-injection blood glucose level, and retains the familiar SUV reference values.
机译:18F-氟脱氧氧基糖正电子发射断层扫描(FDG PET)的标准化摄取值(SUV)广泛用于帮助表征肺结核。本研究的目的是评估血糖水平(Suvgluc)校正的SUV校正的准确性,与其他四种常用的半定量方法相比:最大SUV标准化为体重(SUVMAX),NOODULE与小脑的比率(Suvcer),SUV标准化为体表面积(SUVBSA)和SUV标准化为体重指数(SUVBMI)。 52例肺结核患者具有FDG PET扫描,在7月1日至2015年和2016年7月1日之间连续成像。结节结节的组织病理学结果,在FDG PET扫描后的两个月内获得,展示了10个良性和42个恶性肺结节。 Suvgluc被定义为Suvmax×血糖水平/ 100。对于良性结节的平均Suvmax为2.8,7.7对于恶性结节。在Suvmax(0.84)和Suvcer(0.87)或Suvbsa(0.86)之间发现曲线(AUCS)下的接收器操作特性(ROC)面积没有显着差异,或者在P值为0.05的P值(0.86)之间发现曲线(0.87)或SUVBMI(0.86) ;然而,Suvgluc(0.90)的Roc Auc大于Suvmax的P值为0.03的Suvmax。这些结果表明,Suvgluc可以通过核算患者的血糖水平(BGL)来帮助更准确地表示恶性肺结节的葡萄糖代谢。 Suvgluc方法的简单性避免了另外的参考ROI,使用预先存在的临床数据,即预注射血糖水平,并保留熟悉的SUV参考值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号