首页> 美国卫生研究院文献>Journal of Clinical Medicine >The Influence of NiTi Alloy on the Cyclic Fatigue Resistance of Endodontic Files
【2h】

The Influence of NiTi Alloy on the Cyclic Fatigue Resistance of Endodontic Files

机译:NITI合金对胸腔椎循环疲劳性的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background: The aim of this study was to analyze the influence of NiTi alloy in endodontic rotary instruments on cyclic fatigue resistance. Methods: One hundred and sixty-four (164) sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.08 F2 ProTaper Universal (PTU) (n = 41); B: 25.06 X2 ProTaper Next (PTN) (n = 41); C: 25.08 F2 ProTaper Gold (PTG) (n = 41), and D: 25.06 ProFile Vortex Blue (PVB) (n = 41). A cyclic fatigue device was designed to conduct the static cyclic fatigue tests with stainless steel artificial root canals systems with 250 µm apical diameter, 60° curvature angle, 5 mm radius of curvature, 20 mm length, and 6% (25.06) and 8% taper (25.08). Failure of the endodontic rotary instrument was detected by a single operator through direct observation and was also filmed to allow measurement of the exact time to failure. Results were analyzed using the ANOVA test and Weibull statistical analysis. Results: All pairwise comparisons presented statistically significant differences between the time to failure for the NiTi alloy study groups (p < 0.001), except between the PTN and PVB study groups (p = 0.379). In addition, statistically significant differences between the number of cycles to failure for the NiTi alloy study groups (p < 0.001) were also observed. Conclusions: The NiTi CM-Gold wire alloy of the ProTaper Gold endodontic rotary files resulted in greater resistance to cyclic fatigue than ProFile Vortex Blue, ProTaper Next, and ProTaper Universal endodontic rotary files.
机译:背景:本研究的目的是分析NITI合金在循环疲劳性抗性的胸腔旋转仪器中的影响。方法:选择一百六十四(164)个无菌牙髓旋转文件并分发到以下研究组中:A:25.08 F2蛋白通用(PTU)(n = 41); B:25.06 x2 propaper next(ptn)(n = 41); C:25.08 F2蛋白金(PTG)(PTG)(n = 41)和D:25.06轮廓涡旋蓝色(PVB)(n = 41)。循环疲劳装置旨在通过250μm的绝缘直径,60°曲率角度,曲率半径,20mm长度为5mm,6%(25.06)和8%,进行静循环疲劳试验锥度(25.08)。通过直接观察通过单个操作员检测牙髓旋转仪器的失效,并拍摄以允许测量确切的故障时间。使用ANOVA测试和Weibull统计分析分析了结果。结果:所有成对比较都在PTN和PVB研究组(P = 0.379)之间呈现了NITI合金研究组(P <0.001)的失效时间之间的统计学显着差异。此外,还观察到NITI合金研究组失败的循环次数(P <0.001)之间的统计学上显着差异。结论:Propaper金胸腺旋转文件的NITI CM-金线合金导致抗循环疲劳的抗性大于轮廓涡流,PROTEAP NEXT和PROPAPAPS通用牙髓旋转文件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号