首页> 美国卫生研究院文献>Journal of Clinical Medicine >Influence of the Pecking Motion Frequency on the Cyclic Fatigue Resistance of Endodontic Rotary Files
【2h】

Influence of the Pecking Motion Frequency on the Cyclic Fatigue Resistance of Endodontic Rotary Files

机译:啄运动频率对牙髓旋转锉循环疲劳强度的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Purpose: To analyze the influence of the pecking motion frequency on the cyclic fatigue resistance of endodontic rotary files. Material and Methods: Sixty PlexV 25.06 endodontic rotary files were selected and distributed into three groups: 30 movements/min ( = 20), 60 movements/min ( = 20), and 120 movements/min ( = 20). A dynamic cyclic fatigue device was designed using Computer Aided Design/ Computer Aided Engineering (CAD/CAE) technology and manufactured by 3D impressions to simulate the pecking motion performed by an operator. Failures of the endodontic rotary files were detected by a Light-Emitting Diode (LED)/Light-Dependent Resistor (LDR) system controlled by an Arduino-Driver complex and management software. Endodontic rotary files were tested on an artificial root canal manufactured by wire electrical discharge machining (EDM), with similar dimensions to those of the instrument under examination. Endodontic rotary files were used following the manufacturer’s recommendations. The results were analyzed by ANOVA and Weibull statistics. Results: All pairwise comparisons revealed statistically significant differences in all three variables, except for the difference in the number of cycles between the groups with 60 and 120 movements/min ( = 0.298). The scale distribution parameter of Weibull statistics showed statistically significant differences in all three variables, except for the differences in the number of cycles between groups with 30 and 60 movements/min ( = 0.0722). No statistically significant differences in the three variables were observed for the shape distribution parameter. Conclusion: A low frequency of pecking motion is recommended to reduce the risk of failure of endodontic rotary files associated with cyclic fatigue.
机译:目的:分析啄齿运动频率对牙髓旋转锉耐循环疲劳性的影响。材料和方法:选择60个PlexV 25.06牙髓旋转锉,并将其分为三组:30次/分钟(= 20),60次/分钟(= 20)和120次/分钟(= 20)。动态循环疲劳设备是使用计算机辅助设计/计算机辅助工程(CAD / CAE)技术设计的,并由3D印模制造,以模拟操作员执行的啄食运动。牙髓旋转锉的故障是由受Arduino-Driver复合体和管理软件控制的发光二极管(LED)/光敏电阻(LDR)系统检测到的。牙髓旋转锉在通过电火花加工(EDM)制造的人工根管上进行测试,其尺寸与被检查器械的尺寸相似。按照制造商的建议使用牙髓旋转锉。通过ANOVA和Weibull统计分析结果。结果:所有成对比较均显示所有三个变量在统计学上均存在显着差异,但组之间以60和120次运动/分钟运动的周期数差异(= 0.298)除外。威布尔统计量表的规模分布参数显示所有三个变量在统计上都有显着差异,但每分钟30和60次运动(= 0.0722)的组之间的循环次数不同。在形状分布参数的三个变量中没有观察到统计学上的显着差异。结论:建议进行低频率的啄齿运动,以减少与周期性疲劳相关的牙髓旋转锉失败的风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号