首页> 美国卫生研究院文献>Journal of Applied Clinical Medical Physics >Validation of the preconfigured Varian Ethos Acuros XB Beam Model for treatment planning dose calculations: A dosimetric study
【2h】

Validation of the preconfigured Varian Ethos Acuros XB Beam Model for treatment planning dose calculations: A dosimetric study

机译:验证预配置的Varian Ethos Acuros XB光束模型用于治疗计划剂量计算:一种剂量研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Varian (Palo Alto, California, United States) recently released an online adaptation treatment platform, Ethos, which has introduced a new Dose Preview and Automated Plan Generation module despite sharing identical beam data with the existing Halcyon linac. The module incorporates a preconfigured beam model and the Acuros XB algorithm (Ethos AXB model) to generate final dose calculations from an initial fluence optimization. In this study, we comprehensively validated the accuracy of the Ethos AXB model by comparing it against the Halcyon AXB model, the Halcyon Anisotropic Analytical Algorithm (AAA) model, and measurements acquired on an Ethos linac. Results indicated that the Ethos AXB model demonstrated a comparable if not superior dosimetric accuracy to the Halcyon AXB model in basic and complex calculations, and at the same time its dosimetric accuracy in modulated and heterogeneous plans was better than that of the Halcyon AAA model. Despite the fact that the same algorithm was utilized, the Ethos AXB model and the Halcyon AXB model still exhibited variations across a range of tests, although these variations were predominantly insignificant in the clinical environment. The accuracy of the Ethos AXB model has been successfully verified in this study and is considered appropriate for the current clinical scope. On the basis of this study, clinical physicists can perform a data validation instead of a full data commissioning when implementing the Ethos system, thereby adopting a more efficient approach for Ethos installation.
机译:Varian(Palo Alto,Calofornia,美国)最近发布了一个在线适应治疗平台,虽然具有现有的Halcyon Linac的相同波束数据,但是已经推出了新的剂量预览和自动化计划模块。该模块包含一种预配置的光束模型和ACUROS XB算法(ETHOS AXB模型),以产生从初始注释优化的最终剂量计算。在这项研究中,我们通过将其与Halcyon Axb模型,菱锡各向异性分析算法(AAA)模型进行了全面验证了ETHOS AXB模型的准确性,以及在Ethos Linac上获得的测量。结果表明,ETHOS AXB模型在基本和复杂的计算中对Halcyon AXB模型的罕见剂量精度展示了可比性的,并且在调制和异构计划中的单倍频精度同时优于Halcyon AAA模型。尽管利用了相同的算法,但Ethos Axb模型和Halcyon AXB模型仍在跨越一系列测试的变化,尽管这些变化在临床环境中主要是微不足道的。在本研究中已成功验证了Ethos AXB模型的准确性,被认为是适合目前临床范围的适用性。在本研究的基础上,临床物理学家可以在实施ETHOS系统时执行数据验证,而不是完整的数据调试,从而采用更有效的精神安装方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号