摘要

A new sensit4e and select4e modified screen printed electrodes (MSPEs) and carbon paste electrodes (MCPEs) were studied in order to determine trimbutine maleate (TM) in pure, tablets, urine, and serum samples. These sensors were embodied with multiwalled carbon nanotubes (MWCNTs) since it improved the quality of the sensors in presence of potassium tetrakis (p-chlorophenyl) borate (KTpClPB) ionophore. A good Nernstian response for the constructed sensors, at optimum paste composition, was exhibited for determination of TM in concentration range of 1.5 × 10-7 - 1.0 × 10-2 and 1.0 × 10-7- 1.0 × 10-2 mol L-1 at 25 °C with detection limit of 1.5 × 10-7 and 1.0 × 10-7 mol L-1 for MCPE and MSPE, respect4ely. It seemed that the potential of the electrodes was independent on pH in the range of 2.0-8.0, 2.0-8.5, 2.0-8.5, and 2.0-9.0 g4ing slope as 56.77 ± 1.11, 57.82 ± 0.54, 57.95 ± 0.37, and 58.99 ± 0.28 mV decade-1 for electrodes 1, 2, 3 and 4, respect4ely. MCPEs and MSPEs gave response time about 8 and 6 s with long lifetime (more than 3 and 5 months), respect4ely. A high select4ity of sensors was observed for TM regarding to a large number of interfering species. The constructed sensors were successfully applied for determination of TM in pure form, its pharmaceutical preparations and biological fluids using standard addition, calibration, and potentiometric titration methods with high precision and accuracy. The results showed a good agreement between the proposed method and the HPLC official method.
机译:研究了新的Sensit4E和Select4E改性屏幕印刷电极(MSPES)和碳糊电极(MCPE),以确定纯,片剂,尿液和血清样品中的三丁丁马来丁(TM)。这些传感器均用多壁碳纳米管(MWCNT)体现,因为它改善了在四(氯苯基)硼酸钾(KTPClPB)离子载体存在下传感器的质量。在最佳浆料组合物中,在最佳浆料组合物中呈现出良好的Nernstian响应,用于测定浓度范围为1.5×10-7-1.0×10-2和1.0×10-7-1.0×10-2mol L-的TM。 1在25°C,检测限为1.5×10-7和1.0×10-7摩尔L-1的MCPE和MSPE,相应。似乎电极的电位在pH值中为2.0-8.0,2.0-8.5,2.0-8.5和2.0-9.0g,2.0-9.0g4平斜率为56.77±1.11,57.82±0.54,57.95±0.37和58.99±电极1,2,3和4的0.28 mV十个十个-1,相应。 MCPES和MSPES在长寿(超过3和5个月)的响应时间约为8和6秒,相应。对于大量干扰物种,观察到传感器的高选择性。通过具有高精度和精度的标准添加,校准和电位滴定方法,成功地应用于纯形式,其药物制剂和生物流体中的TM的测定。结果表明,在提出的方法和HPLC官方方法之间表现出良好的一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号