Waste stabilization ponds (WSPs) are widely used for wastewater management owing to the simplicity of their design, low cost and the use of low-skilled operators. This study was carried out to assess the efficiency of a WSP system in reducing the levels of contaminants in hospital wastewater in a rural area of South Africa and to evaluate the current management of the WSP system. Sampling was conducted monthly from January to June 2014. Physicochemical and microbiological parameters were monitored using standard methods. The microbiological parameters (Escherichia coli and enterococci) in the effluent were higher than those in the influent in some sampling months. Also, low pathogen removal efficiency (<1 log reduction) was recorded. The chemical oxygen demand (COD) in the effluent (82–200 mg/L) exceeded the South African Department of Water Affairs for wastewater discharge guideline value of 75 mg/L although reduction efficiencies of 7.7%, 49.1% and 31.1% were observed for the months of February, April and June, respectively. The WSP system did not show a general trend of contaminant reduction except for Zn (5.5–94.8%). The Siloam WSP is not functioning properly and is releasing effluent of poor quality into the receiving river. It is recommended that the WSP system be expanded to cater for the extra load of wastewater it receives, also desludging should be performed as recommended for such systems. Continuous monitoring of the system for compliance to regulatory guideline should be routinely performed.
机译:由于其设计,低成本和低技能操作员的简单,废物稳定池(WSP)广泛用于废水管理。本研究进行了评估WSP系统在降低南非农村地区医院废水水平的效率,并评估WSP系统的目前管理。从2014年1月至6月开始进行抽样。使用标准方法监测物理化学和微生物学参数。流出物中的微生物参数(大肠杆菌和肠球菌)高于一些采样月内流入的微生物参数此外,记录了低病原体去除效率(<1降低降低)。流出物中的化学需氧量(COD)(82-200 mg / L)超过了南非水务部的废水排放准则75毫克/升,虽然未观察到7.7%,49.1%和31.1%的效率分别为2月,4月和6月。除了Zn(5.5-94.8%),WSP系统没有显示出污染物减少的一般趋势。淤泥WSP无法正常运行,并将质量差的污水释放到接收河中。建议将WSP系统扩展到迎合其接收的额外污水负荷,也应按推荐的这种系统进行脱节。应常规执行对符合监管指南的制度持续监测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号