Quantification of the Therapist’s Gentle Pull for Pinch Strength Testing Based on FMA and MMT: An Experimental Study with Healthy Subjects

机译:基于FMA和MMT的捏合强度测试的治疗师温和拉动的定量:健康受试者的实验研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Static pinch strength against a therapist’s gentle pull is evaluated using the pincer grasp component of the Fugl Meyer Assessment (FMA) to assess pinch impairment after stroke. In the pincer grasp component, therapists applied a gentle pull to distinguish between a score of 1 (moderate pinch impairment) and a score of 2 (no pinch impairment). The gentle pull is described as a resistance equivalent to a manual muscle test (MMT) score 4/5. The accepted use of “gentle” as a qualitative description for the pull results is a non-standardized subjective interpretation. The goal of this paper was to determine the quantitative value of the gentle pull applied by the therapists as in their clinical practice using a pinch–pull gripping system. The FMA protocol was used to standardize the body and fingers positions of three occupational therapists who were then instructed to apply a gentle pull of 4/5 MMT using their thumb and index fingers (in a tip-to-tip pinch). The results show that the therapists exerted a mean gentle pull (4/5 MMT score) of 6.34 ± 0.98 N with high reliability and acceptable repeatability. In investigating the ability of healthy subjects to resist the gentle pull, 50 adult male volunteers were instructed to pinch the pincer object and resist a dynamic loading exerted by the pinch–pull gripping system as much as possible to the moment the pincer object slips away. The results show that all subjects were able to exert a pulling force higher than the quantitative value of the gentle pull.
机译:使用Fugl Meyer评估(FMA)的钳子掌握组件评估对治疗师温和拉动的静夹强度,以评估中风后的捏损伤。在夹钳抓握成分中,治疗师施加温和的拉动以区分1(中等夹损损伤)和2的分数(没有夹紧损伤)。温和的拉动被描述为相当于手动肌肉测试(MMT)得分4/5的电阻。接受的使用“温和”作为拉出结果的定性描述是非标准化主观解释。本文的目的是确定治疗师施加的温和拉动的定量值,其临床实践中使用捏夹夹具系统。 FMA议定书用于标准化三个职业治疗师的身体和手指位置,然后使用其拇指和指针(在尖端捏合)中使用拇指和指针施加4/5毫秒的温和拉动。结果表明,治疗师施加平均温和拉(4/5mmt得分)6.34±0.98n,可靠性高,可接受可接受。在调查健康受试者抵抗温和拉动的能力时,指示50个成年男性志愿者夹住钳子物体,并尽可能尽可能地抵抗由夹持器物体滑动的瞬间施加的夹带夹持系统施加的动态载荷。结果表明,所有受试者都能够施加高于温和拉动的定量值的拉力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号