首页> 美国卫生研究院文献>Materials >Temperature Threshold Values of Bone Necrosis for Thermo-Explantation of Dental Implants—A Systematic Review on Preclinical In Vivo Research
【2h】

Temperature Threshold Values of Bone Necrosis for Thermo-Explantation of Dental Implants—A Systematic Review on Preclinical In Vivo Research

机译:牙菌植入物热解体骨质坏死的温度阈值 - 对体内研究临床前的系统综述

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Purpose: Very high or low temperatures will lead to bone damage. The objective of this review was to analyze threshold values for thermal bone necrosis. Methods: Histological animal studies evaluating thermal effects on bone necrosis were selected via electronic and hand searches in English and German language journals until 1 November 2019. The outcome measures were temperature-exposure intervals and laser settings effecting bone damage. Furthermore, investigated parameters were the bone-to-implant contact ratios (BIC) and infrabony pockets around dental implants after thermal treatment. For quality assessment of studies, the CAMARADES study quality checklist was applied. Results: A total of 455 animals in 25 animal studies were included for data extraction after screening of 45 titles from 957 selected titles of the MEDLINE (PubMed), The Cochrane Library, Embase and Web of Science search. The threshold values for bone necrosis ranged between 47 °C and 55 °C for 1 min. A threshold value for cryoinsult and laser treatment has not yet been defined. However, temperatures in the vicinity of 3.5 °C produce a histologically proven effect on the bone and in the surrounding tissue. At 50 °C for 1 min, BIC values significantly decreased and infrabony pockets increased. Bone quality had an influence on the outcome, as cancellous bone suffered higher bone damage from thermal treatment compared to cortical bone. Conclusion: No clear threshold value for bone necrosis is available according to the current literature for warm and cold stimuli. More in-depth and clinical studies are required to provide further insights in assessing the potential of thermal necrosis for implant removal.
机译:目的:非常高或低温会导致骨骼损坏。本综述的目的是分析热骨坏死的阈值。方法:通过英语和德语期刊的电子和手中搜索对骨坏死的热效应进行评估的组织学动物研究,直到2019年11月1日。结果措施是温度暴露间隔和激光环境,影响骨损伤。此外,调查参数是热处理后牙科植入物周围的骨对植入的接触比(BIC)和腹部口袋。对于研究质量评估,应用了CAMARADES研究质量清单。结果:25例动物研究中共有455只动物进行数据提取,从957名选定的Medline(Pubmed),Cochrane图书馆,Embase和Scient Web的搜索中的957个标题。骨坏死的阈值范围为47℃和55℃,1分钟。尚未确定冷冻和激光治疗的阈值。然而,3.5°C附近的温度在骨骼和周围组织上产生组织学证明的效果。在50℃下,1分钟,BIC值显着降低,并且尖头口袋增加。骨质质量对结果有影响,因为与皮质骨相比,松质骨遭受较高的骨损伤。结论:根据当前文献,无明确的骨坏死阈值可根据热敏刺激的目前的文献提供。需要更多的深入和临床研究来提供进一步的见解,评估植入物去除的热坏死潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号