This work demonstrated the feasibility of detectingsevere acute respiratory syndrome associated coronavirus (SARS-CoV) usingmicrocantilever technology by showing that the feline coronavirus (FIP) type Ivirus can be detected by a microcantilever modified by feline coronavirus (FIP)type I anti-viral antiserum. A microcantilever modified by FIP type I anti-viralantiserum was developed for the detection of FIP type I virus. When the FIP typeI virus positive sample is injected into the fluid cell where themicrocantilever is held, the microcantilever bends upon the recognition of theFIP type I virus by the antiserum on the surface of the microcantilever. Anegative control sample that does not contain FIP type I virus did not cause anybending of the microcantilever. The detection limit of the sensor was 0.1µg ml when the assay time was <1 h.
机译:这项工作证明了检测的可行性重症急性呼吸综合征相关冠状病毒(SARS-CoV)使用微悬臂梁技术,通过显示I型猫冠状病毒(FIP)病毒可以通过猫冠状病毒(FIP)修饰的微悬臂梁检测到I型抗病毒抗血清。 FIP I型抗病毒修饰的微悬臂梁开发了抗血清,用于检测FIP I型病毒。当FIP类型I病毒阳性样品被注射到液细胞中保持微悬臂梁,微悬臂梁在识别到FIP I型病毒通过微悬臂梁表面的抗血清产生。一个不含I型FIP病毒的阴性对照样品未引起任何微悬臂弯曲。传感器的检出限为0.1测定时间小于1小时时为µg ml。