首页> 美国卫生研究院文献>Journal of Clinical Laboratory Analysis >New compact‐type latex photometric immunoassay system for hemoglobin and three acute inflammation markers: Neutrophil count C‐reactive protein and anti‐streptolysin O
【2h】

New compact‐type latex photometric immunoassay system for hemoglobin and three acute inflammation markers: Neutrophil count C‐reactive protein and anti‐streptolysin O

机译:用于血红蛋白和三种急性炎症标记物的新型紧凑型乳胶光度免疫分析系统:中性粒细胞计数C反应蛋白和抗链球菌溶血素O

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A new compact‐type latex photometric immunoassay system, SPOTCHEM IM SI‐3510 (ARKRAY, Inc., Kyoto, Japan), which assays three kinds of inflammatory markers—neutrophil count (NPC), C‐reactive protein (CRP), and anti‐streptolysin O (ASO)—was evaluated. Hemoglobin (Hb), which is a good marker for anemia, can also be measured with it. NPC and CRP are measured using antibodies against neutrophilic elastase and CRP, purified streptolysin O was used for ASO determination, and Hb was measured by an azide‐methemoglobin method. Whole blood, serum, and plasma specimens can be used as samples with this system. In this study, whole blood treated with dipotassium ethylenediamine tetraacetic acid was used for evaluation. Linearity and reproducibility were good for all of the items studied. Good correlations were observed between the results obtained by this system and those obtained by routine methods. Since NPC exhibited a high correlation with the routine white blood cell (WBC) counts, it was judged to be useful as a substitute for WBC counting. Since this system is small and easy to operate, and evaluation revealed reliable results, it was judged to be practical for small laboratories, and satellite testing in hospitals and physicians’ office laboratories for patients suspected to have acute inflammation. J. Clin. Lab. Anal. 16:95–102, 2002. © 2002 Wiley‐Liss, Inc.
机译:一种新型的紧凑型乳胶光度免疫分析系统SPOTCHEM IM SI‐3510(爱科来公司,日本京都),可检测三种炎症标记物:中性粒细胞计数(NPC),C反应蛋白(CRP)和抗链球菌溶血素O(ASO)-已评估。血红蛋白(Hb)是贫血的一个很好的标志,也可以用它来测量。使用抗嗜中性弹性蛋白酶和CRP的抗体测量NPC和CRP,使用纯化的链球菌溶血素O进行ASO测定,通过叠氮化物-高铁血红蛋白法测量Hb。全血,血清和血浆标本可用作该系统的样本。在这项研究中,用乙二胺二钾四乙酸处理过的全血用于评估。线性和可重复性对所有研究项目均良好。通过该系统获得的结果与通过常规方法获得的结果之间观察到良好的相关性。由于NPC与常规白细胞(WBC)计数具有高度相关性,因此被认为可替代WBC计数。由于该系统体积小且易于操作,并且评估显示出可靠的结果,因此被认为对于小型实验室是可行的,医院和医师办公室实验室中的卫星测试可用于怀疑患有急性炎症的患者。 J.临床实验室肛门16:95–102,2002.©2002 Wiley-Liss,Inc.

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号