首页> 美国卫生研究院文献>Journal of Clinical Laboratory Analysis >Determination of hydroxycamptothecinum by flow injection analysis with chemiluminescence detection
【2h】

Determination of hydroxycamptothecinum by flow injection analysis with chemiluminescence detection

机译:流动注射-化学发光检测法测定羟基喜树碱

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

An novel analytical method consisting of flow‐injection sampling and chemiluminescence (CL) detection for determination of anticancer drug hydroxycamptothecinum (HCPT) is described. It is based on the CL reaction of potassium permanganate–formaldehyde‐HCPT system. The formaldehyde‐sensitized CL emission mechanism was proposed for HCPT‐potassium permanganate (KMnO )‐HCOH systems by comparing the fluorescence emission with CL spectra. Illuminant was the single‐state bimolecular oxygen, O O ( Δ Δ ), which was from O ( Δ ) produced in the reaction system, and emits CL spectra at 639 nm. The presence of formaldehyde can sensitized CL emission, because it may be to accelerate the generation of O ( Δ ). The optimum conditions for CL emission were investigated and optimized. The CL intensity was correlated linearly with concentration of HCPT in the range of 0.010–60.0 mg L . The determination limit is 0.006 mg L . The relative standard deviation is 1.6% for 11 parallel measurements of 0.20 mg L HCPT standard solution. The proposed method has been applied for the determination of HCPT in pharmaceutical preparations, serum, and urine. The results of the quantitative analysis for HCPT studied using the developed method showed a good agreement with provided by using an official method. J. Clin. Lab. Anal. 21:356–362, 2007. © 2007 Wiley‐Liss, Inc.
机译:介绍了一种由流动注射采样和化学发光(CL)检测组成的新型分析方法,用于测定抗癌药物羟喜树碱(HCPT)。它基于高锰酸钾-甲醛-HCPT体系的CL反应。通过将荧光发射与CL光谱进行比较,针对HCPT-高锰酸钾(KMnO)-HCOH系统提出了甲醛增敏的CL发射机理。发光体是单态双分子氧O ( Δ)(来自反应系统中产生的O(Δ))发出639 nm的CL光谱。甲醛的存在可以促进CL的发射,因为它可能会加速O(Δ)的产生。研究和优化了CL发射的最佳条件。 CL强度与HCPT浓度在0.010-60.0μmgL范围内呈线性相关。测定极限为0.006μL。对于0.20μmgL HCPT标准溶液的11次平行测量,相对标准偏差为1.6%。该方法已用于药物制剂,血清和尿液中HCPT的测定。使用开发的方法对HCPT进行定量分析的结果与使用官方方法提供的结果吻合良好。 J.临床实验室肛门21:356–362,2007.©2007 Wiley-Liss,Inc.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号