首页> 美国卫生研究院文献>Sports >Effect of Thirst-Driven Fluid Intake on 1 H Cycling Time-Trial Performance in Trained Endurance Athletes
【2h】

Effect of Thirst-Driven Fluid Intake on 1 H Cycling Time-Trial Performance in Trained Endurance Athletes

机译:渴求液体摄入对训练有耐力运动员1 H循环时间试验性能的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A meta-analysis demonstrated that programmed fluid intake (PFI) aimed at fully replacing sweat losses during a 1 h high-intensity cycling exercise impairs performance compared with no fluid intake (NFI). It was reported that thirst-driven fluid intake (TDFI) may optimize cycling performance, compared with when fluid is consumed more than thirst dictates. However, how TDFI, compared with PFI and NFI, impacts performance during a 1 h cycling time-trial performance remains unknown. The aim of this study was to compare the effect of NFI, TDFI and PFI on 1 h cycling time-trial performance. Using a randomized, crossover and counterbalanced protocol, 9 (7 males and 2 females) trained endurance athletes (30 ± 9 years; Peak O ∶ 59 ± 8 mL·kg ·min ) completed three 1 h cycling time-trials (30 °C, 50% RH) with either NFI, TDFI or PFI designed to maintain body mass (BM) at ~0.5% of pre-exercise BM. Body mass loss reached 2.9 ± 0.4, 2.2 ± 0.3 and 0.6 ± 0.2% with NFI, TDFI and PFI, respectively. Heart rate, rectal and mean skin temperatures and ratings of perceived exertion and of abdominal discomfort diverged marginally among trials. Mean distance completed (NFI: 35.6 ± 1.9 km; TDFI: 35.8 ± 2.0; PFI: 35.7 ± 2.0) and, hence, average power output maintained during the time-trials did not significantly differ among trials, and the impact of both PFI and TDFI vs. NFI was deemed trivial or unclear. These findings indicate that neither PFI nor TDFI are likely to offer any advantage over NFI during a 1 h cycling time-trial.
机译:一项荟萃分析表明,与没有液体摄入量(NFI)相比,在1小时的高强度自行车运动中完全替代汗水流失的程序化液体摄入量(PFI)会损害性能。据报道,与消耗口渴的情况相比,口渴驱动的液体摄入量(TDFI)可以优化循环性能。但是,与PFI和NFI相比,TDFI如何在1 h循环时间试用期间影响性能。这项研究的目的是比较NFI,TDFI和PFI对1 h循环时间试验性能的影响。使用随机,交叉和平衡的方案,训练了9位(7位男性和2位女性)耐力运动员(30±9岁;峰值O:59±8 mL·kg·min)完成了三个1 h循环时间试验(30°C) NFI,TDFI或PFI可以使体重(BM)保持在运动前BM的〜0.5%左右。使用NFI,TDFI和PFI时,体重减轻分别达到2.9±0.4、2.2±0.3和0.6±0.2%。在各试验中,心率,直肠和平均皮肤温度以及感觉到的劳累和腹部不适的等级略有不同。完成的平均距离(NFI:35.6±1.9 km; TDFI:35.8±2.0; PFI:35.7±2.0),因此,两次试验之间保持的平均功率输出在各次试验中没有显着差异,并且PFI和TDFI对NFI被认为是微不足道或不清楚的。这些发现表明,在1小时的循环时间试验中,PFI和TDFI都不可能比NFI提供任何优势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号