摘要

The development of a simple and low cost electrochemical impedance immunosensor based on screen printed gold electrode for rapid detection of in water is reported. The immunosensor is fabricated by immobilizing anti- antibodies onto a gold surface in a covalent way by the photochemical immobilization technique, a simple procedure able to bind antibodies upright onto gold surfaces. Impedance spectra are recorded in 0.01 M phosphate buffer solution (PBS) containing 10 mM Fe(CN) /Fe(CN) as redox probe. The Nyquist plots can be modelled with a modified Randles circuit, identifying the charge transfer resistance as the relevant parameter after the immobilization of antibodies, the blocking with BSA and the binding of . The introduction of a standard amplification procedure leads to a significant enhancement of the impedance increase, which allows one to measure in drinking water with a limit of detection of 3 × 10 CFU mL while preserving the rapidity of the method that requires only 1 h to provide a “yeso” response. Additionally, by applying the Langmuir adsorption model, we are able to describe the change of in terms of the “effective” electrode, which is modified by the detection of the analyte whose microscopic conducting properties can be quantified.
机译:报道了一种基于丝网印刷金电极的简单,低成本电化学阻抗免疫传感器的开发,该传感器可快速检测水中。通过使用光化学固定技术以共价方式将抗抗体固定在金表面上来制造免疫传感器,光化学固定技术是一种能够将抗体垂直结合到金表面上的简单程序。在包含10 mM Fe(CN)/ Fe(CN)作为氧化还原探针的0.01 M磷酸盐缓冲溶液(PBS)中记录阻抗谱。 Nyquist图可以用改进的Randles电路建模,在固定抗体,BSA阻断和结合后,将电荷转移阻力确定为相关参数。标准扩增程序的引入导致阻抗增加的显着增强,这使得人们可以在饮用水中进行测量,检测限为3×10 CFU mL,同时保留了仅需1小时即可提供的方法的快速性。回答“是/否”。另外,通过应用Langmuir吸附模型,我们能够描述“有效”电极的变化,该变化通过检测其微观导电特性可以量化的分析物进行修改。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号