首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Comparing Pulsed-Field Gel Electrophoresis with Multilocus Sequence Typing spa Typing Staphylococcal Cassette Chromosome mec (SCCmec) Typing and PCR for Panton-Valentine Leukocidin arcA and opp3 in Methicillin-Resistant Staphylococcus aureus Isolates at a U.S. Medical Center
【2h】

Comparing Pulsed-Field Gel Electrophoresis with Multilocus Sequence Typing spa Typing Staphylococcal Cassette Chromosome mec (SCCmec) Typing and PCR for Panton-Valentine Leukocidin arcA and opp3 in Methicillin-Resistant Staphylococcus aureus Isolates at a U.S. Medical Center

机译:将脉冲场凝胶电泳与多位点序列分型spa分型葡萄球菌盒式染色体mec(SCCmec)分型和PCR进行比较以在美国的耐甲氧西林金黄色葡萄球菌医学中心分离Panton-Valentine LeukocidinarcA和opp3。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Methicillin-resistant Staphylococcus aureus (MRSA) has become a common cause of skin infections and invasive infections in community dwellers in the United States since the late 1990s. Isolates characterized as USA300 by pulsed-field gel electrophoresis (PFGE) are the predominant strain type in these infections. USA100 and USA500 strains commonly cause health care-associated infections. We compared PFGE with a number of other methods of genotyping in a sample of 149 clinical MRSA isolates from the University of Chicago Medical Center. The 5 USA500 isolates yielded 3 spa types and 2 multilocus sequence types (MLSTs). Among the 24 USA100 isolates, 21 (88%) were of spa type t002, 19 (79%) were of ST5, 2 carried arcA and opp3, and 1 was Panton-Valentine leukocidin positive (PVL+). Among the 102 USA300 isolates, 96 (94%) were of ST8 and 94 (92%) were of spa type t008. The combination of traits that provided the best sensitivity (98%), specificity (97%), positive predictive value (PPV) (99%), and negative predictive value (NPV) (95%) for identifying USA300 isolates were the presence of the arcA gene and the presence of the PVL genes (area under the curve, 0.980; 95% confidence interval [CI], 0.955 to 1.0). PFGE did not delineate a homogeneous group of MRSA genetic backgrounds, as documented for other typing methods, particularly for USA500 and USA100 pulsotypes. Documenting the presence of arcA and PVL genes by PCR was an efficient and accurate means of identifying USA300 in a collection of MRSA isolates in which USA300 is common. None of the tested genotyping methods provided an accurate means of identifying the next most common PFGE-based backgrounds, USA100 and USA500.
机译:自1990年代后期以来,耐甲氧西林的金黄色葡萄球菌(MRSA)已成为美国社区居民皮肤感染和侵入性感染的常见原因。在这些感染中,以脉冲场凝胶电泳(PFGE)为特征的USA300分离株是主要的菌株类型。 USA100和USA500菌株通常引起与医疗保健相关的感染。我们在来自芝加哥大学医学中心的149个临床MRSA分离株的样本中,将PFGE与许多其他基因分型方法进行了比较。这5个USA500菌株产生了3种水疗类型和2种多基因座序列类型(MLST)。在24种USA100菌株中,有21种(88%)是t002型水疗中心,有19种(79%)是ST5型,2种携带arcA和opp3,其中1种是Panton-Valentine leukocidin阳性(PVL + )。在102株USA300菌株中,有96株(94%)是ST8,94株(92%)是t008型。可提供鉴定USA300分离株的最佳敏感性(98%),特异性(97%),阳性预测值(PPV)(99%)和阴性预测值(NPV)(95%)的特征组合为arcA基因和PVL基因的存在(曲线下面积0.980; 95%置信区间[CI]为0.955至1.0)。 PFGE并未描绘出同质的MRSA遗传背景,如其他分型方法所记录,尤其是USA500和USA100脉冲型。通过PCR记录arcA和PVL基因的存在是鉴定USA300常见的MRSA分离物集合中USA300的有效且准确的方法。没有一种经过测试的基因分型方法提供准确的方法来鉴定下一个最常见的基于PFGE的背景,USA100和USA500。