Successful Use of an eSheath for Failed Introduction of the Evolut R Valve during Transfemoral Transcatheter Aortic Valve Implantation

机译:成功使用eSheath进行经股动脉经导管主动脉瓣植入术后未能成功引入Evolut R瓣膜

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

An 86-year-old man with severe, symptomatic aortic stenosis underwent a 29 mm Evolut R (Medtronic, Minneapolis, MN, USA) implantation using the right femoral artery approach. Pre-procedural computed tomography angiography showed significant tortuosity, but adequate diameters (>7.0 mm) and minimal calcification in both external iliac arteries ( ). After a Lunderquist Extra-Stiff Wire Guide (Cook Medical, Bloomington, IN, USA) was inserted to straighten the anatomy and increase stability, neither the 14Fr Inline nor 18 Fr sheath could be inserted into the right iliac artery due to strong resistance. The angiography showed a severe accordion phenomenon in the right iliac artery that prevented device insertion ( ). To overcome the phenomenon, a 14Fr eSheath (Edwards Lifesciences, Irvine, CA, USA) was successfully inserted with some resistance. A 29 mm Evolut R e-Sheath was then smoothly implanted without any major vascular complications ( ).
机译:一位患有严重症状性主动脉瓣狭窄的86岁男子使用右股动脉入路植入了29 mm Evolut R(Medtronic,明尼阿波利斯,明尼苏达州,美国)。术前计算机断层扫描血管造影显示出明显的曲折性,但两个external外动脉均具有足够的直径(> 7.0 mm)和最小的钙化()。插入Lunderquist特硬线材导引器(Cook Medical,美国印第安纳州布卢明顿)以拉直解剖结构并提高稳定性之后,由于14Fr内联线和18 Fr护套均不能牢固插入,因此阻力很强。血管造影显示右动脉有严重的手风琴现象,阻止了器械的插入()。为了克服该现象,成功插入了14Fr eSheath(Edwards Lifesciences,Irvine,CA,美国)并产生了一些阻力。然后将29 mm的Evolut R e-Sheath顺利植入,而没有任何严重的血管并发症()。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号