Isometric knee muscle strength measurement using a belt-stabilized hand-helddynamometer and an isokinetic dynamometer with and without trunk fixation: investigationof agreement of measurement values and factors influencing measurement

机译:使用带稳定装置的手持式等距膝盖肌肉力量测量测功机和带和不带躯干固定的等速测功机:研究值与影响测量的因素之间的一致性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

[Purpose] The purpose of this study was to examine the agreement between the valuesobtained by using a hand-held dynamometer with a belt (belt-HHD) and an isokineticdynamometer (IKD) for the measurement of isometric knee flexion and extension musclestrength. We also studied the factors influencing the measurement. [Participants andMethods] Overall, 26 healthy young adults (16 males, 10 females) participated in thestudy; the mean age was 21 years. Knee flexion and extension muscle strength were measuredby three methods: 1) belt-HHD, 2) conventional IKD with the participant sitting on anattached chair (conv-IKD), and 3) modified IKD with the participant sitting on the samemat table as HHD (mod-IKD). [Results] In the measurement of knee extension, mod-IKD andconv-IKD showed a fixed bias and a proportional bias, conv-IKD and belt-HHD showed a fixedbias, and belt-HHD and mod-IKD showed a fixed bias. In the measurement knee flexion,conv-IKD and mod-IKD showed a proportional bias, belt-HHD and conv-IDK showed a fixedbias, and mod-IKD and belt-HHD showed a fixed bias. In each combination, the measuredvalues were larger in the latter due to errors. However, the types and values of errorsdiffered when analysis was conducted based on gender. [Conclusion] In order to increasethe agreement between the values, it is necessary to revise the fixing method of thetrunk, and the fixing method of the belt and the sensor pad in belt-HHD.
机译:[目的]本研究的目的是检验价值观之间的一致性通过使用带有皮带(皮带HHD)和等速的手持测功机获得测力计(IKD)用于测量等距膝盖屈伸肌强度。我们还研究了影响测量的因素。 [参加者和方法]总共有26名健康的年轻人(男16例,女10例)参加了研究。研究;平均年龄为21岁。测量膝关节屈伸肌的力量通过以下三种方法:1)腰带HHD,2)传统IKD,参与者坐在附加椅子(conv-IKD),和3)修改IKD,参与者坐在同一椅子上垫表为HHD(mod-IKD)。 [结果]在膝盖伸展的测量中,mod-IKD和conv-IKD显示固定偏差和比例偏差,conv-IKD和皮带HHD显示固定偏差偏差,而皮带HHD和mod-IKD显示固定偏差。在测量膝盖弯曲度时conv-IKD和mod-IKD显示成比例的偏差,belt-HHD和conv-IDK显示出固定值偏差,mod-IKD和Belt-HHD显示出固定偏差。在每种组合中,由于错误,后者的值较大。但是,错误的类型和值根据性别进行分析的方式有所不同。 [结论]为了增加价值观之间的一致性,有必要修改皮带以及HHD皮带中皮带和传感器垫的固定方法。