首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Characteristics of the m2000 Automated Sample Preparation and Multiplex Real-Time PCR System for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae
【2h】

Characteristics of the m2000 Automated Sample Preparation and Multiplex Real-Time PCR System for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae

机译:用于检测沙眼衣原体和淋病奈瑟氏菌的m2000自动样品制备和多重实时PCR系统的特征

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We evaluated a new real-time PCR-based prototype assay for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae developed by Abbott Molecular Inc. This assay is designed to be performed on an Abbott m2000 real-time instrument system, which consists of an m2000sp instrument for sample preparation and an m2000rt instrument for real-time PCR amplification and detection. The limit of detection of this prototype assay was determined to be 20 copies of target DNA for both C. trachomatis and N. gonorrhoeae, using serially diluted linearized plasmids. No cross-reactivity could be detected when 55 nongonococcal Neisseria isolates and 3 non-C. trachomatis Chlamydia isolates were tested at 1 million genome equivalents per reaction. Concordance with the Roche Amplicor, BDProbeTec ET, and Gen-Probe APTIMA Combo 2 tests was assessed using unlinked/deidentified surplus clinical specimens previously analyzed with these tests. For C. trachomatis, concordance for positive results ranged from 93.7% to 100%, while concordance for negative results ranged from 98.2% to 100%. For N. gonorrhoeae, concordance for positive and negative results ranged from 91.4% to 100% and 99.3% to 100%, respectively. A workflow analysis of the prototype assay was conducted to obtain information on throughput under laboratory conditions. At 48 samples/run, the time to first result for both C. trachomatis and N. gonorrhoeae was 4.5 h. A total of 135 patient specimens could be analyzed in 8.9 h, with 75 min of hands-on time. This study demonstrated the technical and clinical feasibility of the new Abbott real-time PCR C. trachomatis/N. gonorrhoeae assay.
机译:我们评估了由Abbott Molecular Inc.开发的基于实时PCR的新型原型检测方法,用于检测沙眼衣原体和淋病奈瑟菌。该检测方法旨在在Abbott m2000实时仪器系统上进行,该系统由m2000sp仪器组成用于样品制备和用于实时PCR扩增和检测的m2000rt仪器。使用连续稀释的线性化质粒,该原型测定的检测极限被确定为沙眼衣原体和淋病奈瑟氏球菌的目标DNA的20个拷贝。 55株非淋球菌奈瑟菌和3株非C菌未检测到交叉反应。每个反应以1百万个基因组当量测试沙眼衣原体分离株。与Roche Amplicor,BDProbeTec ET和Gen-Probe APTIMA Combo 2测试的一致性,是使用之前已通过这些测试分析的未链接/不确定的多余临床标本进行评估的。对于沙眼衣原体,阳性结果的一致性范围为93.7%至100%,而阴性结果的一致性范围为98.2%至100%。对于淋病奈瑟菌,阳性和阴性结果的一致性分别为91.4%至100%和99.3%至100%。进行了原型测定的工作流程分析,以获取有关实验室条件下通量的信息。以48个样本/次运行,沙眼衣原体和淋病奈瑟氏球菌首次检测结果的时间为4.5小时。可以在8.9小时内分析135个患者标本,动手时间为75分钟。这项研究证明了新型雅培实时定量PCR沙眼衣原体/ N的技术和临床可行性。淋病测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号