首页> 美国卫生研究院文献>Diagnostics >Feasibility Evaluation of Commercially Available Video Conferencing Devices to Technically Direct Untrained Nonmedical Personnel to Perform a Rapid Trauma Ultrasound Examination
【2h】

Feasibility Evaluation of Commercially Available Video Conferencing Devices to Technically Direct Untrained Nonmedical Personnel to Perform a Rapid Trauma Ultrasound Examination

机译:商用视频会议设备对未经训练的非医疗人员进行技术指导以进行快速创伤超声检查的可行性评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Point-of-care ultrasound (POCUS) is a rapidly expanding discipline that has proven to be a valuable modality in the hospital setting. Recent evidence has demonstrated the utility of commercially available video conferencing technologies, namely, FaceTime (Apple Inc, Cupertino, CA, USA) and Google Glass (Google Inc, Mountain View, CA, USA), to allow an expert POCUS examiner to remotely guide a novice medical professional. However, few studies have evaluated the ability to use these teleultrasound technologies to guide a nonmedical novice to perform an acute care POCUS examination for cardiac, pulmonary, and abdominal assessments. Additionally, few studies have shown the ability of a POCUS-trained cardiac anesthesiologist to perform the role of an expert instructor. This study sought to evaluate the ability of a POCUS-trained anesthesiologist to remotely guide a nonmedically trained participant to perform an acute care POCUS examination. A total of 21 nonmedically trained undergraduate students who had no prior ultrasound experience were recruited to perform a three-part ultrasound examination on a standardized patient with the guidance of a remote expert who was a POCUS-trained cardiac anesthesiologist. The examination included the following acute care POCUS topics: (1) cardiac function via parasternal long/short axis views, (2) pneumothorax assessment via pleural sliding exam via anterior lung views, and (3) abdominal free fluid exam via right upper quadrant abdominal view. Each examiner was given a handout with static images of probe placement and actual ultrasound images for the three views. After a brief 8 min tutorial on the teleultrasound technologies, a connection was established with the expert, and they were guided through the acute care POCUS exam. Each view was deemed to be complete when the expert sonographer was satisfied with the obtained image or if the expert sonographer determined that the image could not be obtained after 5 min. Image quality was scored on a previously validated 0 to 4 grading scale. The entire session was recorded, and the image quality was scored during the exam by the remote expert instructor as well as by a separate POCUS-trained, blinded expert anesthesiologist. A total of 21 subjects completed the study. The average total time for the exam was 8.5 min (standard deviation = 4.6). A comparison between the live expert examiner and the blinded postexam reviewer showed a 100% agreement between image interpretations. A review of the exams rated as three or higher demonstrated that 87% of abdominal, 90% of cardiac, and 95% of pulmonary exams achieved this level of image quality. A satisfaction survey of the novice users demonstrated higher ease of following commands for the cardiac and pulmonary exams compared to the abdominal exam. The results from this pilot study demonstrate that nonmedically trained individuals can be guided to complete a relevant ultrasound examination within a short period. Further evaluation of using telemedicine technologies to promote POCUS should be evaluated.
机译:即时护理超声(POCUS)是一门快速发展的学科,已被证明是医院环境中的一种宝贵手段。最近的证据表明,商用视频会议技术(即FaceTime(Apple Inc.,库比蒂诺,加利福尼亚州,美国)和Google Glass(Google Inc.,Mountain View,加利福尼亚州,美国))的实用性可以使专业POCUS审查员进行远程指导新手医学专家。但是,很少有研究评估使用这些远程超声技术来指导非医学新手进行心脏,肺和腹部评估的急性护理POCUS检查的能力。此外,很少有研究表明受过POCUS培训的心脏麻醉师具有执行专家指导员的作用。这项研究试图评估接受POCUS培训的麻醉师远程指导未经医学培训的参与者进行急性护理POCUS检查的能力。总共招募了21名没有接受过超声检查的未经医学专业训练的本科生,在一名由POCUS训练过的心脏麻醉专家的远程专家的指导下,对标准化患者进行了三部分超声检查。该检查包括以下急诊POCUS主题:(1)通过胸骨旁长/短轴视图进行心功能检查;(2)通过胸膜滑动检查通过前肺视图进行气胸评估;(3)通过右上腹腹腔检查腹部游离液视图。为每个检查员提供了三个位置的探针讲义和实际超声图像的讲义。在简短的8分钟的远程超声技术教程之后,与专家建立了联系,并通过急诊POCUS考试对他们进行了指导。当专业超声医师对所获得的图像感到满意时,或者如果专业超声医师确定5分钟后仍无法获得图像,则认为每个视图都是完整的。图像质量以先前验证的0到4的等级评分。整个过程都被记录下来,并且在检查过程中,由远程专家讲师以及由一名经过POCUS培训的盲眼专家麻醉师对图像质量进行了评分。共有21位受试者完成了研究。考试的平均总时间为8.5分钟(标准差= 4.6)。现场专家审查员与盲检查员审查员之间的比较显示,图像解释之间的一致性为100%。对三项或三项以上考试的审查表明,腹部检查的87%,心脏检查的90%和肺部检查的95%达到了此图像质量水平。对新手用户的满意度调查显示,与腹部检查相比,对心脏和肺部检查进行命令遵循的难度更高。这项初步研究的结果表明,可以指导未经医学培训的人员在短时间内完成相关的超声检查。应该评估使用远程医疗技术促进POCUS的进一步评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号