首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Susceptibility Testing with the Manual Mycobacteria Growth Indicator Tube (MGIT) and the MGIT 960 System Provides Rapid and Reliable Verification of Multidrug-Resistant Tuberculosis
【2h】

Susceptibility Testing with the Manual Mycobacteria Growth Indicator Tube (MGIT) and the MGIT 960 System Provides Rapid and Reliable Verification of Multidrug-Resistant Tuberculosis

机译:使用手动分枝杆菌生长指示器管(MGIT)和MGIT 960系统进行的药敏试验可快速可靠地验证耐多药结核病

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The objective of the study was to compare the manual Mycobacteria Growth Indicator Tube (MGIT) method and the BACTEC MGIT 960 system to the BACTEC 460 method for susceptibility testing of Mycobacterium tuberculosis. The evaluation was based on testing of 36 M. tuberculosis strains with various susceptibilities to isoniazid (INH), rifampin (RMP), ethambutol (EMB), and streptomycin (SM). In addition, five of the strains generating discrepant results in testing for EMB were analyzed for heteroresistance. For INH, the susceptibility test results obtained by the MGIT 960 and the manual MGIT systems agreed with the BACTEC 460 results in 94 and 97% of the cases, respectively. The results of susceptibility to RMP were all in agreement. For SM, 78 and 72% of the results obtained by the MGIT 960 and the manual MGIT systems, respectively, agreed with the BACTEC 460 results. In contrast, less than 80% of the results for susceptibility to EMB obtained by the two MGIT methods agreed with the BACTEC 460 results. All five strains analyzed for EMB heteroresistance were found to consist of resistant and susceptible subpopulations. The average turnaround times were 6.4 days for the MGIT 960 system, 6.5 for the manual MGIT system, and 8.7 days for the BACTEC 460 method. Both MGIT methods can be regarded as accurate and rapid alternatives to the BACTEC 460 method for detection of strains resistant to INH and RMP. However, more studies are needed for solving the problems associated with susceptibility testing to EMB and SM.
机译:该研究的目的是比较手动分枝杆菌生长指示器管(MGIT)方法和BACTEC MGIT 960系统与BACTEC 460方法对结核分枝杆菌药敏性的测试。该评估基于对36种对异烟肼(INH),利福平(RMP),乙胺丁醇(EMB)和链霉素(SM)敏感的结核分枝杆菌菌株的测试。此外,分析了五个在EMB测试中产生差异结果的菌株的异抗性。对于INH,MGIT 960和手动MGIT系统获得的药敏试验结果分别与BACTEC 460的结果相符,分别为94%和97%。对RMP的敏感性结果全部一致。对于SM,分别由MGIT 960和手动MGIT系统获得的结果的78%和72%与BACTEC 460的结果一致。相比之下,通过两种MGIT方法获得的EMB敏感性结果不到80%与BACTEC 460结果一致。发现所有五种EMB异抗性分析菌株均由抗性和易感亚群组成。 MGIT 960系统的平均周转时间为6.4天,手动MGIT系统的平均周转时间为6.5天,而BACTEC 460方法的平均周转时间为8.7天。两种MGIT方法都可以视为BACTEC 460方法的准确,快速替代方法,用于检测对INH和RMP耐药的菌株。然而,需要更多的研究来解决与EMB和SM的药敏试验有关的问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号