首页> 美国卫生研究院文献>Anatomy Cell Biology >Use of the orbito-occipital line as an alternative to the Frankfort line
【2h】

Use of the orbito-occipital line as an alternative to the Frankfort line

机译:使用眶枕线替代法兰克福线

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Frankfort horizontal line, the line passing through the orbitale and porion, is one of the most widely used intracranial landmarks in cephalometric analysis. This study investigated the use of the orbito-occipital line extending from the orbitale to the external occipital protuberance as a novel horizontal line of the skull for substituting the Frankfort horizontal line. We evaluated the reproducibility of the new landmark and measured the angle between the orbito-occipital line and the Frankfort line. This study was conducted on 170 facial computed tomography (CT) scans of living adults from the Department of Plastic Surgery. After three-dimensionally reconstructed images were obtained from facial CT, the porion, orbitale, and external occipital protuberance were indicated by two observers twice. The angles between the orbito-meatal line (inferior orbital rim to porion; the Frankfort line) and the orbito-occipital line (inferior orbital rim to external occipital protuberance) were measured. There was no significant intraobserver or interobserver bias. The overall angle between the Frankfort line and orbito-occipital line was −0.5°±2.2° (mean±standard deviation). There was no statistically significant difference among side and sex. This study demonstrated good reproducibility of a new landmark—the external occipital protuberance—tested to replace the porion. The orbito-occipital line is a reliable, reproducible, and easily identifiable line, and has potential as a novel standard horizontal line to replace or at least supplement the Frankfort line in anthropological studies and certain clinical applications.
机译:法兰克福水平线(穿过眼眶和部分)是头颅测量分析中使用最广泛的颅内标志之一。这项研究调查了从枕骨到枕外隆起的眶枕线作为颅骨的新型水平线替代Frankfort水平线的用途。我们评估了新地标的再现性,并测量了眶枕线与法兰克福线之间的夹角。这项研究是对来自整形外科的成年成年人进行的170项面部计算机断层扫描(CT)扫描进行的。从面部CT获得三维重建图像后,两名观察员两次指示了部分,眼眶和枕外突出。测量眼眶金属线(眼眶下缘至门廊;法兰克福线)与眶枕线(眼眶下缘至枕外突出)之间的夹角。观察者间或观察者间无明显偏倚。法兰克福线与眶枕线之间的总角度为-0.5°±2.2°(平均值±标准偏差)。性别和性别之间无统计学差异。这项研究表明,新的标志物-外部枕骨隆起-可以替代部分,具有良好的可重复性。眶枕线是一种可靠,可复制且易于识别的线,在人类学研究和某些临床应用中,有可能作为新型标准水平线替代或至少补充法兰克福线。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号