摘要

We conducted a 12-month prospective study comparing two approaches to the detection of Mycobacterium avium in the blood of human immunodeficiency virus type 1-infected patients, namely, a lytic centrifugation system combined with Middlebrook solid culture medium (the conventional procedure) and the nonradiometric BACTEC 9000 MB system. Species identification relied on 16S rRNA probe hybridization and cell wall fatty acids chromatography. M. avium was isolated in 17 of 345 (5%) blood specimens by the BACTEC 9000 MB automated system and in 14 of 345 (4%) blood specimens by the conventional procedure (nonsignificant, χ2 test). Detection time was 16 ± 6 days by the BACTEC 9000 MB automated system and 27 ± 3 days by the conventional procedure (P < 0.001, Student t test). Non-M. avium mycobacteria were not recovered during the study period. Contamination rate was 8% (30 specimens) by the BACTEC 9000 MB system and 0% by the conventional procedure, indicating the necessity of using an antibiotic mixture (PANTA, consisting of polymyxin B, amphotericin B, nalidixic acid, trimethoprim, and azlocillin). Working time was 1 min 30 s by the BACTEC 9000 MB system and 8 min by the conventional procedure, which was 1.8 times more expensive than the BACTEC system. Use of the BACTEC 9000 MB system increased the sensitivity of M. avium detection and reduced detection time in blood culture.
机译:我们进行了一项为期12个月的前瞻性研究,比较了两种检测人类免疫缺陷病毒1型感染患者血液中鸟分枝杆菌的方法,即与Middlebrook固体培养基结合的裂解离心系统(常规程序)和非放射线BACTEC 9000 MB系统。物种鉴定依赖于16S rRNA探针杂交和细胞壁脂肪酸色谱。通过BACTEC 9000 MB自动化系统在345个血液样本中(5%)分离出鸟分​​枝杆菌,通过常规方法在345个血液样本中(14%)(4%)分离出(无显着性,χ 2 测试)。 BACTEC 9000 MB自动化系统的检测时间为16±6天,常规方法为27±3天(P <0.001,Student t检验)。非男。在研究期间未发现鸟分枝杆菌。 BACTEC 9000 MB系统的污染率为8%(30个标本),常规方法为0%,表明必须使用抗生素混合物(PANTA,由多粘菌素B,两性霉素B,萘啶酸,甲氧苄啶和阿洛西林组成) 。 BACTEC 9000 MB系统的工作时间为1分30 s,而传统程序为8分钟,这是BACTEC系统的1.8倍。 BACTEC 9000 MB系统的使用提高了鸟分枝杆菌检测的灵敏度,并缩短了血液培养中的检测时间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号