首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Rapid detection of group A streptococci: comparative performance by nurses and laboratory technologists in pediatric satellite laboratories using three test kits.
【2h】

Rapid detection of group A streptococci: comparative performance by nurses and laboratory technologists in pediatric satellite laboratories using three test kits.

机译:A组链球菌的快速检测:护士和实验室技术人员在儿童卫星实验室中使用三种测试套件的比较性能。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Rapid tests for detecting group A streptococci in throat swabs are often performed outside hospitals or commercial laboratories by individuals with little or no technical training. We compared the abilities of nurses and technologists to perform and interpret three commercial kits (Directigen 1-2-3, ICON Strep A, and Culturette Brand 10-Minute Strep A ID) in three hospital satellite locations (the emergency department, a walk-in emergency clinic, and a general pediatric clinic). When the three tests were compared with culture, the sensitivities of the tests as performed by nurses and technologists, respectively, were 39 versus 44% for Directigen, 55 versus 51% for Culturette, and 72 versus 39% for ICON. A significant difference in sensitivity was found only with ICON tests. This result was largely explained by the tendency of technologists to test moist swabs, while nurses generally processed dry swabs; ICON test sensitivity was significantly greater with dry swabs. The specificities of Directigen and ICON tests performed by nurses and technologists were high (97 to 100%). The difference in the specificities of the Culturette test as determined from results obtained by nurses and technologists (80 versus 98%) was due to the tendency of one nurse to overinterpret the latex agglutination reaction. Analysis of the accuracies of the tests during practice periods compared with the accuracies of the tests during the study periods revealed statistically significant improvement in test performance. We conclude that these tests are specific but not sensitive when performed by nurses and technologists in satellite laboratories. With one exception, nurses and technologists performed the tests with comparable accuracy after brief training periods.
机译:快速检测喉咙拭子中A组链球菌的方法通常是在医院或商业实验室外进行的,几乎没有经过技术培训的人员或没有进行过技术培训的人员。我们比较了护士和技术人员在三个医院附属地点(急诊室,散步室,医院,医院,医院和医院)执行和解释三种商业工具包(Directigen 1-2-3,ICON Strep A和Culturette Brand 10分钟Strep A ID)的能力。在急诊室和普通儿科诊所)。当将这三个测试与培养进行比较时,由护士和技术人员进行的测试的敏感性分别为Directigen为39%vs.44%,Culturette为55%vs.51%,ICON为72%vs.39%。仅通过ICON测试发现灵敏度存在显着差异。技术人员倾向于测试湿拭子,而护士通常处理干拭子,这在很大程度上解释了这一结果。干拭子的ICON测试灵敏度明显更高。护士和技术人员进行的Directigen和ICON测试的特异性很高(97%至100%)。根据护士和技术人员的结果确定的培养液测试特异性的差异(80%对98%)是由于一位护士倾向于过度解释乳胶凝集反应。对练习期间的测试准确性与研究期间的测试准确性进行分析后,发现测试性能在统计上有显着提高。我们得出的结论是,当由卫星实验室的护士和技术人员执行这些测试时,这些测试是特定的,但不敏感。除了一个例外,护士和技术人员经过短暂的培训后,以相当的准确性进行了测试。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号