首页> 美国卫生研究院文献>other >Simultaneous quantitation of 17α-hydroxyprogesterone caproate 17α-hydroxyprogesterone and progesterone in human plasma using high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS)
【2h】

Simultaneous quantitation of 17α-hydroxyprogesterone caproate 17α-hydroxyprogesterone and progesterone in human plasma using high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS)

机译:使用高效液相色谱-质谱法(HPLC-MS / MS)同时定量人血浆中的己酸17α-羟孕酮17α-羟孕酮和孕酮

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A sensitive and specific assay method for the simultaneous quantitation of 17α-hydroxyprogesterone caproate (17-OHPC), 17α-hydroxyprogesterone (17-OHP), and progesterone (P) in human plasma using high performance liquid chromatography and tandem mass spectrometry (LC-MS/MS) was developed and validated. Plasma samples were processed by a solid phase extraction (SPE) procedure using Oasis HLB extraction cartridge prior to chromatography. Medroxyprogestrone acetate (MPA) was used as the internal standard. The compounds were separated using Waters C18 Symmetry analytical column (3.5 μm, 2.1 × 50 mm) using a gradient elusion with a mobile phase consisting of 5% methanol in water [A] and methanol [B], with 0.01% ammonium hydroxide being added to both [A] and [B], at a flow rate 0.3 ml/min. The retention times for 17-OHPC, 17-OHP, P and MPA were 4.5, 1.5, 2.5 and 2.2 min respectively, with a total run time of 7 min. The analytes were detected Micromass Quattro Micro triple quadrupole mass spectrometer in positive electron spray ionization (ESI) mode using multiple reaction monitoring (MRM). The extracted ions monitored following MRM transitions were m/z 429.10→313.10 for 17-OHPC, m/z 331.17→97.00 for 17-OHP, m/z 315.15→109.00 for P and m/z 387.15→327.25 for MPA (IS). The assay was linear over the range 1 – 200 ng/ml for 17-OHPC and 17-OHP, and 2 – 400 ng/ml for P, when 0.4 ml of plasma was used in the extraction. The overall intra- and inter-day assay variation was <15%. No significant variation in the concentration of 17-OHPC, 17-OHP or P was observed with different sample processing and / or storage conditions. This method is simple, allows easy accurate and reproducible measurement of 17-OHPC, 17-OHP and P simultaneously in human plasma, and is used to evaluate the pharmacokinetics of 17-OHPC in pregnant subjects.
机译:使用高效液相色谱和串联质谱(LC-MS)同时定量测定人血浆中己酸17α-羟孕酮(17-OHPC),17α-羟孕酮(17-OHP)和孕酮(P)的灵敏且特异的测定方法MS / MS)的开发和验证。在色谱之前,使用Oasis HLB提取柱通过固相萃取(SPE)程序处理血浆样品。醋酸甲羟孕酮(MPA)用作内标。使用Waters C18对称性分析柱(3.5μm,2.1×50 mm)分离化合物,使用梯度洗脱,流动相由在水中的5%甲醇[A]和甲醇[B]组成,并添加0.01%氢氧化铵[A]和[B]的流量均以0.3 ml / min的速率输送。 17-OHPC,17-OHP,P和MPA的保留时间分别为4.5、1.5、2.5和2.2分钟,总运行时间为7分钟。使用多反应监测(MRM)在正电子喷雾电离(ESI)模式下对Micromass Quattro Micro三重四极杆质谱仪进行了检测。在MRM转换后监测的提取离子对于17-OHPC为m / z 429.10→313.10,对于17-OHP为m / z 331.17→97.00,对于P为m / z 315.15→109.00,对于MPA(IS)为m / z 387.15→327.25 。当提取液中使用0.4 ml血浆时,对于17-OHPC和17-OHP,测定范围为1-200 ng / ml,对于P为2-400 ng / ml,呈线性。日内和日间分析的总体变化<15%。在不同的样品处理和/或储存条件下,未观察到17-OHPC,17-OHP或P浓度的显着变化。该方法简单易行,可在人血浆中同时简便,准确,可重复地测量17-OHPC,17-OHP和P,可用于评估17-OHPC在孕妇体内的药代动力学。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号