首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Comparison of a radiometric method (BACTEC) and conventional culture media for recovery of mycobacteria from smear-negative specimens.
【2h】

Comparison of a radiometric method (BACTEC) and conventional culture media for recovery of mycobacteria from smear-negative specimens.

机译:放射法(BACTEC)与常规培养基用于从涂片阴性标本中恢复分枝杆菌的比较。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The BACTEC system and three conventional media (Middlebrook 7H10, selective Middlebrook 7H11 [S7H11], and Lowenstein-Jensen [LJ] were compared for their mean recovery times and recovery rates of mycobacteria from acid-fast, smear-negative clinical specimens. Of the 71 smear-negative, culture-positive specimens recovered from 2,165 submitted smear-negative cultures, the BACTEC system detected 71.8%, compared with 88.7% for the conventional three-medium system. When media were individually compared, BACTEC medium (Middlebrook 7H12) was more successful in recovering mycobacteria (71.8%) than was LJ (62%), Middlebrook medium 7H10 (55.9%), or Middlebrook S7H11 medium (52.1%). Middlebrook 7H11 medium containing sodium selenate was also evaluated and did not increase the recovery rate or decrease the recovery time of mycobacterial species when compared with LJ, Middlebrook 7H10, S7H11, and 7H12 media. The mean detection time for the BACTEC system was less than that by conventional methods for the seven species of mycobacteria recovered. Detection times for Mycobacterium tuberculosis on the BACTEC system and conventional cultural systems were 13.7 and 26.3 days, respectively.
机译:比较了BACTEC系统和三种常规培养基(Middlebrook 7H10,选择性Middlebrook 7H11 [S7H11]和Lowenstein-Jensen [LJ])在耐酸,涂片阴性临床标本中分枝杆菌的平均回收时间和回收率。从2165个提交的涂片阴性培养物中回收到71份涂片阴性,培养阳性的标本,BACTEC系统检出了71.8%,而传统的三培养基系统则为88.7%,单独比较培养基时,BACTEC培养基(Middlebrook 7H12)为与LJ(62%),Middlebrook培养基7H10(55.9%)或Middlebrook S7H11培养基(52.1%)相比,分枝杆菌的恢复成功率更高(71.8%),还评估了含硒酸钠的Middlebrook 7H11培养基,并未提高回收率。与LJ,Middlebrook 7H10,S7H11和7H12培养基相比,分枝杆菌物种的恢复时间有所缩短或减少,BACTEC系统的平均检测时间比常规方法减少了。恢复了七种分枝杆菌。在BACTEC系统和常规培养系统上结核分枝杆菌的检测时间分别为13.7天和26.3天。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号