首页> 美国卫生研究院文献>Journal of Dental Research Dental Clinics Dental Prospects >Effect of screw access hole preparation on fracture load of implant-supported zirconia-based crowns: an in vitro study
【2h】

Effect of screw access hole preparation on fracture load of implant-supported zirconia-based crowns: an in vitro study

机译:螺钉孔制备对植入物支撑的氧化锆基牙冠断裂载荷的影响:体外研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background. Fracture load of implant-supported restorations is an important factor in clinical success. This study evaluated the effect of two techniques for screw access hole preparation on the fracture load of cement-screw-retained implant-supported zirconia-based crowns.>Methods. Thirty similar cement-screw-retained implant-supported zirconia-based maxillary central incisor crowns were evaluated in three groups of 10. Group NH: with no screw access holes for the control; Group HBS: with screw access holes prepared with a machine before zirconia sintering; Group HAS: with screw access holes prepared manually after zirconia sintering. In group HBS, the access holes were virtually designed and prepared by a computer-assisted design/computer-assisted manufacturing system. In group HAS, the access holes were manually prepared after zirconia sintering using a diamond bur. The dimensions of the screw access holes were equal in both groups. The crowns were cemented onto same-size abutments and were then subjected to thermocycling. The fracture load values of the crowns were measured using a universal testing machine. Data were analyzed with ANOVA and Tukey test (P < 0.05).>Results. The mean fracture load value for the group NH was 888.37 ± 228.92 N, which was the highest among the groups, with a significant difference (P < 0.0001). The fracture load values were 610.48 ± 125.02 N and 496.74 ± 104.10 Nin the HBS and HAS groups, respectively, with no significant differences (P = 0.44).>Conclusion. Both techniques used for preparation of screw access holes in implant-supported zirconia-based crowns decreased the fracture load.
机译:>背景。植入物支持的修复体的骨折负荷是临床成功的重要因素。这项研究评估了两种螺钉通孔制备技术对水泥螺钉固位种植体支撑的氧化锆基牙冠的断裂载荷的影响。>方法。。三十种类似的水泥螺钉固位种植体支撑的冠状动脉氧化锆基上颌中切牙牙冠分为3组,每组10组。 HBS组:在氧化锆烧结前用机器准备的螺丝孔; HAS组:氧化锆烧结后,需手动准备螺丝孔。在HBS组中,检修孔实际上是由计算机辅助设计/计算机辅助制造系统设计和准备的。在HAS组中,使用金刚石钻头在氧化锆烧结后手动准备出入孔。两组螺丝孔的尺寸均相等。将牙冠粘结到相同尺寸的基台上,然后进行热循环。使用万能试验机测量牙冠的断裂载荷值。数据采用方差分析和Tukey检验进行分析(P <0.05)。>结果。 NH组的平均骨折负荷值为888.37±228.92 N,在各组中最高,差异有统计学意义(P <0.0001)。 HBS组和HAS组的断裂载荷值分别为610.48±125.02 N和496.74±104.10 N,无显着性差异(P = 0.44)。>结论。这两种技术均用于制备螺钉通道。植入物支持的氧化锆基牙冠中的骨折可降低骨折负荷。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号