首页> 美国卫生研究院文献>Journal of Dental Research Dental Clinics Dental Prospects >In Vitro Investigation of Heat Transfer Phenomenon in Human Immature Teeth
【2h】

In Vitro Investigation of Heat Transfer Phenomenon in Human Immature Teeth

机译:人体未成熟牙齿中传热现象的体外研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background and aims. Heat generated within tooth during clinical dentistry can cause thermally induced damage to hard and soft components of the tooth (enamel, dentin and pulp). Geometrical characteristics of immature teeth are different from those of mature teeth. The purpose of this experimental and theoretical study was to investigate thermal changes in immature permanent teeth during the use of LED light-curing units (LCU).>Materials and methods. This study was performed on the second mandibular premolars. This experimental investiga-tion was carried out for recording temperature variations of different sites of tooth and two dimensional finite element models were used for heat transfer phenomenon in immature teeth. Sensitivity analysis and local tests were included in the model validation phase.> Results. Overall, thermal stimulation for 30 seconds with a low-intensity LED LCU increased the temperature from 28°C to 38°C in IIT (intact immature tooth) and PIT (cavity-prepared immature tooth). When a high-intensity LED LCU was used, tooth temperature increased from 28°C to 48°C. The results of the experimental tests and mathematical modeling illustrated that using LED LCU on immature teeth did not have any detrimental effect on the pulp temperature.> Conclusion. Using LED LCU in immature teeth had no effect on pulp temperature in this study. Sensitivity analysis showed that variations of heat conductivity might affect heat transfer in immature teeth; therefore, further studies are required to determine thermal conductivity of immature teeth.
机译:>背景和目的。在临床牙科过程中,牙齿内部产生的热量可对牙齿的硬质和软质成分(牙釉质,牙本质和牙髓)产生热致损伤。未成熟牙齿的几何特征与成熟牙齿的几何特征不同。这项实验和理论研究的目的是研究使用LED光固化单元(LCU)期间未成熟恒牙的热变化。>材料和方法。该研究是针对第二颗下颌前磨牙进行的。 。进行该实验研究以记录牙齿不同部位的温度变化,并使用二维有限元模型来分析未成熟牙齿的热传递现象。模型验证阶段包括敏感性分析和局部测试。>结果。总体而言,在低强度LED LCU上进行30秒的热刺激会使IIT中的温度从28°C升高到38°C(完整的未成熟牙齿)和PIT(蛀牙准备的未成熟牙齿)。当使用高强度LED LCU时,牙齿温度从28°C升高到48°C。实验测试和数学建模的结果表明,在未成熟的牙齿上使用LED LCU对牙髓温度没有任何有害影响。>结论。 在本研究中,在未成熟牙齿中使用LED LCU对牙髓温度没有影响。敏感性分析表明,导热系数的变化可能会影响未成熟牙齿的传热;因此,需要进一步的研究来确定未成熟牙齿的热导率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号