Nowadays, almost all persons with diabetes—at least those using antidiabetic drug therapy—use one of a plethora of meters commercially available for self-monitoring of blood glucose. The accuracy of blood glucose (BG) measurement using these meters has been presumed to be adequate; that is, the accuracy of these devices was not usually questioned until recently. Health authorities in the United States (Food and Drug Administration) and in other countries are currently endeavoring to tighten the requirements for the accuracy of these meters above the level that is currently stated in the standard ISO 15197. At first glance, this does not appear to be a problem and is hardly worth further consideration, but a closer look reveals a considerable range of critical aspects that will be discussed in this commentary. In summary, one could say that as a result of modern production methods and ongoing technical advances, the demands placed on the quality of measurement results obtained with BG meters can be increased to a certain degree. One should also take into consideration that the system accuracy (which covers many more aspects as the analytical accuracy) required to make correct therapeutical decisions certainly varies for different types of therapy. At the end, in addition to analytical accuracy, thorough and systematic training of patients and regular refresher training is important to minimize errors. Only under such circumstances will patients make appropriate therapeutic interventions to optimize and maintain metabolic control.
机译:如今,几乎所有的糖尿病患者(至少是使用抗糖尿病药物治疗的患者)都使用市售的大量血糖仪之一来自我监测血糖。假定使用这些仪表测量血糖(BG)的准确性足够。也就是说,通常直到最近才对这些设备的准确性提出质疑。美国(食品和药物管理局)和其他国家/地区的卫生当局目前正在努力将这些仪表的精度要求提高到高于标准ISO 15197中规定的水平。乍一看,这似乎没有出现这是一个问题,几乎不值得进一步考虑,但仔细观察就会发现将在本评论中讨论的许多关键方面。总之,可以说,由于现代生产方法和持续的技术进步,对BG表获得的测量结果质量的要求可以在一定程度上增加。还应该考虑到,做出正确的治疗决策所需的系统准确性(涵盖许多方面作为分析准确性)对于不同类型的治疗方法肯定有所不同。最后,除了分析准确性外,对患者进行全面而系统的培训以及定期的进修培训对于最大程度地减少错误也很重要。只有在这种情况下,患者才能进行适当的治疗干预,以优化和维持代谢控制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号