首页> 美国卫生研究院文献>other >The Utility of Ambulatory ElectrocardiographicMonitoring for Detecting Silent Arrhythmias andClarifying Symptom Mechanism in an UrbanElderly Population with Heart Failure andHypertension: Clinical Implications
【2h】

The Utility of Ambulatory ElectrocardiographicMonitoring for Detecting Silent Arrhythmias andClarifying Symptom Mechanism in an UrbanElderly Population with Heart Failure andHypertension: Clinical Implications

机译:门诊心电图的效用监测检测静音和心律失常明确症状机制的城市老年人口心力衰竭和高血压:临床意义

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: Atrial and ventriclar tachyarrhythmias, as well as bradyarrhythmias, in the elderly with heart failure (HF) and/or hypertension (HTN) have been well documented. However, the frequency of these arrhythmias, whether silent or symptomatic, and their association with subsequent cardiac events has not been well defi ned in patients 65 years or older with HF and other cardiovascular risk factors. >Objective: To assess the value of 2 weeks of remote, transtelephonic cardiac monitoring for detecting arrhythmias in an elderly, urban population living with HF. >Methods: Fi” y-four patients with a history of systolic HF and/or HTN were consented and enrolled. All wore an auto triggered cardiac loop monitor for 2 weeks that captures EKG data and both silent and symptomatic arrhythmias were recorded. >Results: Mean age was 73 ± 6 years with 59% of subjects were females, 74% Hispanic, 22% black, and 4% white/other. All patients had HF and 94% had HTN. From the cardiac monitoring, 72% demonstrated ectopic atrial and ventricular activity, and 1 paroxysmal episode of atrial fi brillation was documented. In addition, 3 subjects had signifi cant non-sustained ventricular tachycardia, and 4 individuals had severe bradycardia recorded on cardiac monitoring. These 7 individuals underwent placement of an implantable cardioverter defi brillator (ICD) or pacemaker based on the documented arrhythmias which may have otherwise gone undetected. >Conclusions: A substantial proportion of patients exhibited cardiac arrhythmias. Future morbidity was prevented because of the detection of arrhythmias on monitoring that led to specifi c therapies such as pacemaker or ICD implantation which otherwise may not have been implemented.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号