首页> 美国卫生研究院文献>other >Imaging the Human Aqueous Humor Outflow Pathway in Human Eyes by Three Dimensional Micro-Computed Tomography (3D micro-CT)
【2h】

Imaging the Human Aqueous Humor Outflow Pathway in Human Eyes by Three Dimensional Micro-Computed Tomography (3D micro-CT)

机译:通过三维微型计算机断层扫描(3D Micro-CT)在人眼中成像人眼中的人类水中流出途径

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The site of outflow resistance leading to elevated intraocular pressure in primary open angle glaucoma is believed to be located in the region of Schlemm’s canal inner wall endothelium, its basement membrane and the adjacent juxtacanalicular tissue. Evidence also suggests collector channels and intrascleral vessels may have a role in intraocular pressure in both normal and glaucoma eyes. Traditional imaging modalities limit the ability to view both proximal and distal portions of the trabecular outflow pathway as a single unit. In this study, we examined the effectiveness of three-dimensional micro-computed tomography (3D micro-CT) as a potential method to view the trabecular outflow pathway. Two normal human eyes were used: one immersion fixed in 4% paraformaldehyde, and one with anterior chamber perfusion at 10 mmHg followed by perfusion fixation in 4% paraformaldehyde/2% glutaraldehyde. Both eyes were postfixed in 1% osmium tetroxide, and scanned with 3D micro-CT at 2 µm or 5 µm voxel resolution. In the immersion fixed eye, 24 collector channels were identified with an average orifice size of 27.5 ± 5 µm. In comparison, the perfusion fixed eye had 29 collector channels with a mean orifice size of 40.5 ± 13 µm. Collector channels were not evenly dispersed around the circumference of the eye. There was no significant difference in the length of Schlemm’s canal in the immersed versus the perfused eye (33.2 versus 35.1 mm). Structures, locations and size measurements identified by 3D micro-CT were confirmed by correlative light microscopy. These findings confirm 3D micro-CT can be used effectively for the non-invasive examination of the trabecular meshwork, Schlemm’s canal, collector channels and intrascleral vasculature that comprise the distal outflow pathway. This imaging modality will be useful for noninvasive study of the role of the trabecular outflow pathway as a whole unit.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号