首页> 美国卫生研究院文献>Journal of Digital Imaging >A Feasibility Study of Real-Time Remote CT Reading for Suspected Acute Appendicitis Using an iPhone
【2h】

A Feasibility Study of Real-Time Remote CT Reading for Suspected Acute Appendicitis Using an iPhone

机译:使用iPhone实时远程CT读取可疑急性阑尾炎的可行性研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We aimed to evaluate the feasibility of an iPhone-based remote control system as a real-time remote computed tomography (CT) reading tool for suspected appendicitis using a third-generation (3G) network under suboptimal illumination. One hundred twenty abdominal CT scans were selected; 60 had no signs of appendicitis, whereas the remaining 60 had signs of appendicitis. The 16 raters reviewed the images using the liquid crystal display (LCD) monitor of a picture archiving and communication system (PACS) workstation, as well as using an iPhone connected to the PACS workstation via a remote control system. We graded the probability of the presence of acute appendicitis for each examination using a five-point Likert scale. The overall sensitivity and specificity for the diagnosis of suspected appendicitis using the iPhone and the LCD monitor were high, and they were not significantly different (sensitivity P = 1.00, specificity P = 0.14). The average areas under the receiver operating characteristic curves for all CT readings with the iPhone and LCD monitor were 0.978 (confidence interval 0.965–0.991) and 0.974 (0.960–0.988), respectively, and the two devices did not have significantly different diagnostic performances (P = 0.55). The inter-rater agreement for both devices was very good; the kappa value for the iPhone was 0.809 (0.793–0.826), and that for the LCD monitor was 0.817 (0.801–0.834). Each rater had moderate-to-very good intra-observer agreement between the two devices. We verified the feasibility of an iPhone-based remote control system as a real-time remote CT reading tool for identifying suspected appendicitis using a 3G network and suboptimal illumination.
机译:我们旨在评估在次优照明下使用第三代(3G)网络的基于iPhone的远程控制系统作为可疑阑尾炎的实时远程计算机断层扫描(CT)阅读工具的可行性。选择了一百二十次腹部CT扫描。 60例无阑尾炎迹象,而其余60例有阑尾炎迹象。 16位评分者使用图片存档和通信系统(PACS)工作站的液晶显示器(LCD)监控器,以及通过远程控制系统连接到PACS工作站的iPhone,查看了图像。我们使用五点李克特量表对每次检查中出现急性阑尾炎的可能性进行分级。使用iPhone和LCD监视器诊断可疑阑尾炎的总体敏感性和特异性均很高,且两者之间无显着差异(敏感性P = 1.00,特异性P = 0.14)。 iPhone和LCD显示器的所有CT读数的接收器工作特性曲线下的平均面积分别为0.978(置信区间0.965-0.991)和0.974(0.960-0.988),并且两种设备的诊断性能没有显着差异( P = 0.55)。两种设备的评估者之间的协议非常好。 iPhone的Kappa值为0.809(0.793–0.826),而LCD显示器的Kappa值为0.817(0.801–0.834)。每个评估者在两个设备之间都具有中等到非常好的观察者内部协议。我们验证了基于iPhone的远程控制系统作为使用3G网络和次佳照明来识别可疑阑尾炎的实时远程CT读取工具的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号