An increasing number of patients undergoing proton radiotherapy have cardiac implantable electrical devices (CIEDs). We recently encountered a situation in which a high-voltage coil on a lead from an implanted cardiac defibrillator was located within the clinical treatment volume for a patient receiving proton radiotherapy for esophageal cancer. To study the effects of the lead on the dose delivery we placed a high-Z CIED lead at both the center and the distal edge of a clinical spread-out Bragg peak (SOBP) in a water phantom, in both a stationary position and with the lead moving in a periodic pattern to simulate cardiorespiratory movement. We then calculated planned doses using a commercial proton treatment planning system (TPS) and compared them with the doses delivered in the phantom, measured using radiographic film.Dose profiles from TPS-calculated and measured dose distributions showed large pertubrations in the delivered proton dose in the vicinity of the CIED lead when it was not moving. The TPS predicted perturbations up to 20% and measurements revealed perturbations up to 35%. However, the perturbations were less than 3% when the lead was moving. Greater dose perturbations were seen when the lead was placed at the distal edge of the SOBP than when it was placed in the center of the SOBP.We conclude that although cardiorespiratory motion of the lead mitigates some of the perturbations, the effects of the leads should be considered and steps taken to reduce these effects during the treatment planning process.
机译:越来越多的经过质子放射疗法的患者具有心脏可植入电气装置(CIEDS)。我们最近遇到了一种情况,其中来自植入的心脏除颤器的铅上的高压线圈位于临床处理体积内,用于接受对食管癌的质子放射疗法的患者。为了研究铅对剂量递送的效果,我们将高Z CIED引线放置在临床扩散布拉格峰(SOBP)的临床扩散布拉格峰(SOBP)的远端处,在静止位置和以周期性模式移动以模拟心肺运动的铅。然后我们使用商业质子治疗计划系统(TPS)计算计划剂量,并将它们与在幻像中递送的剂量进行比较,使用射线照相膜测量。来自TPS计算和测量剂量分布的糖分子在递送的质子剂量中显示出大的静脉化当它没有移动时,射灯的附近。 TPS预测扰动高达20%,测量显示扰动高达35%。然而,当铅在移动时,扰动小于3%。当铅被置于SOBP的远端边缘时,观察到更大的剂量扰动,而不是将其放置在SOBP的中心。我们得出结论,尽管铅的心肺运动减轻了一些扰动,但引线的影响应该被考虑并采取的步骤减少治疗计划过程中的这些效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号