首页> 美国卫生研究院文献>other >In vivo passive mechanical properties of skeletal muscle improve with massage-like loading following eccentric exercise
【2h】

In vivo passive mechanical properties of skeletal muscle improve with massage-like loading following eccentric exercise

机译:在偏心运动后的按摩样装载的骨骼肌的体内被动力学性能

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

A quasi-linear viscoelasticity (QLV) model was used to study passive time-dependent responses of skeletal muscle to repeated massage-like compressive loading (MLL) following damaging eccentric exercise. Six skeletally mature rabbits were surgically instrumented with bilateral peroneal nerve cuffs for stimulation of the hindlimb tibialis anterior (TA) muscles. Following the eccentric exercise, rabbits were randomly assigned to a four-day MLL protocol mimicking deep effleurage (0.5 Hz, 10 N for 15 min or for 30 min). The contralateral hindlimb served as the exercised, no-MLL control for both MLL conditions. Viscoelastic properties of the muscle pre-exercise, post-exercise on Day 1, and pre- and post-MLL Day 1 through Day 4 were determined with ramp-and-hold tests. The instantaneous elastic response (AG0) increased following exercise (p <0.05) and decreased due to both the 15 min and 30 min four-day MLL protocols (p<0.05). Post-four days of MLL the normalized AG0 decreased from post-exercise (Day 1, 248.5%) to the post-MLL (Day 4, 98.5%) (p<0.05), compared to the no-MLL group (Day 4, 222.0%) (p<0.05). Exercise and four-day MLL showed no acute or cumulative effects on the fast and slow relaxation coefficients (p>0.05). This is the first experimental evidence of the effect of both acute (daily) and cumulative changes in viscoelastic properties of intensely exercised muscle due to ex vivo MLL. It provides a starting point for correlating passive muscle properties with mechanical effects of manual therapies, and may shed light on design and optimization of massage protocols.
机译:拟线性粘弹性(QLV)模型用于研究骨骼肌对破坏性离心运动后重复按摩样压缩负荷(MLL)的被动时间依赖性反应。六只骨骼成熟的兔子通过双侧腓神经袖口进行手术器械刺激,以刺激后肢胫前肌(TA)。进行离心运动后,将兔子随机分配为期四天的MLL方案,以模仿深部发汗(0.5 Hz,10 N持续15分钟或30分钟)。对侧后肢在两种MLL情况下均作为运动的无MLL对照。通过斜坡保持测试确定肌肉在运动前,运动后第1天以及运动前和运动后第1天至第4天的粘弹性质。运动后的瞬时弹性反应(AG0)升高(p <0.05),并且由于15天和30分钟的4天MLL方案而降低(p <0.05)。与非MLL组(第4天)相比,MLL四天后的标准化AG0从运动后(第1天,248.5%)下降到MLL后(第4天,98.5%)(p <0.05)。 222.0%)(p <0.05)。运动和四天的运动量测验显示对快速和慢速松弛系数无急性或累积影响(p> 0.05)。这是由于离体MLL引起的剧烈运动的肌肉的粘弹性的急性(每日)和累积变化的影响的第一个实验证据。它提供了将被动肌肉特性与手动疗法的机械效果相关联的起点,并且可能为按摩方案的设计和优化提供启示。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号