Nose/throat-swabs from 1049 patients were screened for MRSA using CHROMagar MRSA, LightCycler Advanced MRSA, and Detect-Ready MRSA. Results were compared to the CHROMagar MRSA results, which was set as reference system. MRSA was detected in 3.05% of the patients with CHROMagar MRSA. LightCycler MRSA Advanced showed a higher clinical sensitivity (84.38%) than Detect-Ready MRSA (57.69%).The negative predictive values were high for both tests (>98%). The specificity and the positive predictive value were higher for the Detect-Ready MRSA test than for the LightCycler MRSA test (99.59% and 78.95% versus 98.52% and 64.29%). For routine screening LightCycler MRSA Advanced proved to be more efficient in our clinical setting as the clinical sensitivity was much higher than the sensitivity of Detect-Ready MRSA. CHROMagar MRSA detected more MRSA positive samples than both PCR methods, leading to the conclusion that the combination of PCR with cultural screening is still the most reliable way for the detection of MRSA. LightCycler MRSA Advanced was faster and needed less hands-on time. The advantage of Detect-Ready MRSA was the additional identification of methicillin-sensitive S.aureus (here in 34.63% of the samples), an information which can be possibly used for reducing the risk of postoperative infections in surgical patients in future.
机译:使用CHROMagar MRSA,LightCycler Advanced MRSA和Detect-Ready MRSA对1049名患者的鼻/咽拭子进行了MRSA筛查。将结果与设置为参考系统的CHROMagar MRSA结果进行比较。在3.05%的CHROMagar MRSA患者中检测到MRSA。 LightCycler MRSA Advanced的临床敏感性(84.38%)比可检测的MRSA更高(57.69%)。两种测试的阴性预测值都很高(> 98%)。可直接检测的MRSA检测的特异性和阳性预测值高于LightCycler MRSA检测(99.59%和78.95%,而98.52%和64.29%)。对于常规筛查,LightCycler MRSA Advanced在我们的临床环境中被证明是效率更高的,因为其临床灵敏度远高于“检测就绪” MRSA的灵敏度。 CHROMagar MRSA比两种PCR方法都能检测到更多的MRSA阳性样品,从而得出结论,PCR与培养物筛选相结合仍然是检测MRSA的最可靠方法。 LightCycler MRSA Advanced更快,需要更少的动手时间。可直接检测的MRSA的优点是可以进一步鉴定对甲氧西林敏感的金黄色葡萄球菌(在此样本中占34.63%),该信息将来可用于减少手术患者术后感染的风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号