Although many synthetic calcium indicators are available, a search for compounds with improved characteristics continues. Here, we describe the synthesis and properties of Asante Calcium Red-1 (ACR-1) and its low affinity derivative (ACR-1-LA) created by linking BAPTA to seminaphthofluorescein. The indicators combine a visible light (450–540 nm) excitation with deep-red fluorescence (640 nm). Upon Ca2+ binding, the indicators raise their fluorescence with longer excitation wavelengths producing higher responses. Although the changes occur without any spectral shifts, it is possible to ratio Ca2+-dependent (640 nm) and quasi-independent (530 nm) emission when using visible (<490 nm) or multiphoton (~780 nm) excitation. Therefore, both probes can be used as single wavelength or, less dynamic, ratiometric indicators. Long indicator emission might allow easy [Ca2+]i measurement in GFP expressing cells. The indicators bind Ca2+ with either high (Kd=0.49±0.07 μM; ACR-1) or low affinity (Kd=6.65±0.13 μM; ACR-1-LA). Chelating Zn2+ (Kd =0.38±0.02 nM) or Mg2+ (Kd ~5 mM) slightly raises and binding Co2+ quenches dye fluorescence. New indicators are somewhat pH-sensitive (pKa=6.31±0.07), but fairly resistant to bleaching. The probes are rather dim, which combined with low AM ester loading efficiency, might complicate in situ imaging. Despite potential drawbacks, ACR-1 and ACR-1-LA are promising new calcium indicators.
机译:尽管有许多合成的钙指示剂,但仍在寻找具有改善特性的化合物。在这里,我们描述了Asante钙红1(ACR-1)及其低亲和力衍生物(ACR-1-LA)的合成和性质,该合成是通过将BAPTA与半萘荧光素连接而产​​生的。指示剂结合了可见光(450–540 nm)激发和深红色荧光(640 nm)。在Ca 2 + 结合后,指示剂随着激发波长的增加而增强其荧光,从而产生更高的响应。尽管变化发生时没有任何光谱偏移,但是当使用可见光(<490 nm)或多光子()时,可以将Ca 2 + 依赖性(640 nm)和准非依赖性(530 nm)发射的比率〜780 nm)激发。因此,两个探头都可以用作单波长或动态性较低的比例指示器。较长的指示剂发射可能使GFP表达细胞中的[Ca 2 + ] i测量变得容易。指示剂以高(Kd = 0.49±0.07μM; ACR-1)或低亲和力(Kd = 6.65±0.13μM; ACR-1-LA)结合Ca 2 + 。螯合Zn 2 + (Kd = 0.38±0.02 nM)或Mg 2 + (Kd〜5 mM)略微升高并结合Co 2 + 淬灭染料荧光。新的指示剂在某种程度上对pH敏感(pKa = 6.31±0.07),但相当耐漂白。探针相当暗,加上低AM酯负载效率,可能会使原位成像复杂化。尽管存在潜在的缺点,但ACR-1和ACR-1-LA仍有望成为新的钙指示剂。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号