首页> 美国卫生研究院文献>other >Internal Jugular Vein Blood Flow in Multiple Sclerosis Patients and Matched Controls
【2h】

Internal Jugular Vein Blood Flow in Multiple Sclerosis Patients and Matched Controls

机译:多发性硬化症患者的颈内静脉血流及相关对照

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of the study was to investigate the Internal Jugular Veins dynamics using contrast enhanced ultrasonography in Multiple Sclerosis patients, clinically isolated syndrome patients and healthy controls. Contrast enhanced ultrasonography imaging of the Internal Jugular Vein was performed in fifty-eight patients with Multiple Sclerosis, seven clinically isolated syndrome patients and in thirteen healthy controls. Time-intensity curves were quantified using a semi-automated method and compared with clinical disease outcomes. Wash-out parameters were calculated and six Time-intensity curves shapes were created. Significantly reduction of wash-out rate in Internal Jugular Veins was detected in Multiple Sclerosis patients compared to healthy controls [22.2% (2.7%–65.9%) vs. 33.4% (16.2%–76.8%); P<0.005]. Internal Jugular Vein enhancement was heterogeneous in patients with Multiple Sclerosis and consisted of slow wash-out Time-intensity curves shapes, compared with almost only one type of Time-intensity curves shape in control subjects that correspond to fast enhancement and fast wash-out. The vein wash-in parameters were similar in Multiple Sclerosis group compared with controls. A significant correlation was found between Internal Jugular Vein wash-out and level of disability (R = −0.402, p<0.05). Contrast enhanced ultrasonography of the Internal Jugular Vein with time intensity curve analysis revealed alterations of cerebral venous outflow in Multiple Sclerosis patients, however mechanisms that determine this condition remains unclear.
机译:该研究的目的是利用超声造影检查多发性硬化症患者,临床孤立综合征患者和健康对照者的颈内静脉动力学。 58例多发性硬化症患者,7例临床孤立综合征患者和13例健康对照者进行了颈内静脉超声造影增强成像。使用半自动化方法对时间强度曲线进行定量,并与临床疾病结果进行比较。计算洗出参数并创建六个时间强度曲线形状。与健康对照组相比,多发性硬化症患者的颈内静脉冲洗率显着降低[22.2%(2.7%–65.9%)与33.4%(16.2%–76.8%); P <0.005]。与多发性硬化症患者相比,颈内静脉内的增强是异质的,由缓慢的洗出时间-强度曲线形状组成,而对照受试者中几乎只有一种类型的时间-强度曲线形状对应于快速增强和快速洗出。与对照组相比,多发性硬化症组的静脉冲洗参数相似。发现颈内静脉冲洗与残疾水平之间存在显着相关性(R = -0.402,p <0.05)。颈内静脉超声造影与时间强度曲线分析的对比显示多发性硬化症患者脑静脉流出的改变,但是确定这种情况的机制仍不清楚。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号