Tensile Mechanical Properties of Swine Cortical Mandibular Bone

机译:猪皮质下颌骨的拉伸力学性能

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Temporary orthodontic mini implants serve as anchorage devices in orthodontic treatments. Often, they are inserted in the jaw bones, between the roots of the teeth. The stability of the mini implants within the bone is one of the major factors affecting their success and, consequently, that of the orthodontic treatment. Bone mechanical properties are important for implant stability. The aim of this study was to determine the tensile properties of the alveolar and basal mandible bones in a swine model. The diametral compression test was employed to study the properties in two orthogonal directions: mesio-distal and occluso-gingival. Small cylindrical cortical bone specimens (2.6 mm diameter, 1.5 mm thickness) were obtained from 7 mandibles using a trephine drill. The sites included different locations (anterior and posterior) and aspects (buccal and lingual) for a total of 16 specimens from each mandible. The load-displacement curves were continuously monitored while loading half of the specimens in the oclluso-gingival direction and half in the mesio-distal direction. The stiffness was calculated from the linear portion of the curve. The mesio-distal direction was 31% stiffer than the occluso-gingival direction. The basal bone was 40% stiffer than the alveolar bone. The posterior zone was 46% stiffer than the anterior zone. The lingual aspect was stiffer than the buccal aspect. Although bone specimens do not behave as brittle materials, the diametral compression test can be adequately used for determining tensile behavior when only small bone specimens can be obtained. In conclusion, to obtain maximal orthodontic mini implant stability, the force components on the implants should be oriented mostly in the mesio-distal direction.
机译:临时性正畸微型植入物在正畸治疗中用作锚固装置。通常,它们被插入牙根之间的颚骨中。微型植入物在骨头中的稳定性是影响其成功的主要因素之一,因此也是正畸治疗的主要因素。骨机械性能对于植入物的稳定性很重要。这项研究的目的是确定猪模型中牙槽骨和基底下颌骨的拉伸特性。使用径向压缩试验来研究两个正交方向的特性:近中向和咬合齿龈。使用环钻从7个下颌骨中获得小的圆柱形皮质骨标本(直径2.6 mm,厚度1.5 mm)。这些部位包括不同的位置(前和后)和方面(颊和舌),每个下颌骨总共有16个标本。连续监测载荷-位移曲线,同时沿咬合-齿龈方向加载一半样本,沿近中-远端方向加载一半样本。从曲线的线性部分计算刚度。远中方向的硬度比咬合齿龈方向的硬度高31%。基骨比牙槽骨坚硬40%。后部区域的硬度比前部区域高46%。舌面比颊面硬。尽管骨标本不能用作脆性材料,但当只能获得较小的骨标本时,径向压缩试验可以适当地用于确定拉伸性能。总之,要获得最大的正畸微型种植体稳定性,种植体上的力分量应主要沿近中向定向。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号