首页> 美国卫生研究院文献>other >Repeatability of Quantitative Sodium Magnetic Resonance Imaging for Estimating Pseudo-Intracellular Sodium Concentration and Pseudo-Extracellular Volume Fraction in Brain at 3 T
【2h】

Repeatability of Quantitative Sodium Magnetic Resonance Imaging for Estimating Pseudo-Intracellular Sodium Concentration and Pseudo-Extracellular Volume Fraction in Brain at 3 T

机译:定量钠磁共振成像在3 T估算脑中伪细胞内钠浓度和伪细胞外体积分数的可重复性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The purpose of this study is to assess the repeatability of the quantification of pseudo-intracellular sodium concentration (C1) and pseudo-extracellular volume fraction (α) estimated in brain in vivo using sodium magnetic resonance (MRI) at 3 T. Eleven healthy subjects were scanned twice, with two sodium MRI acquisitions (with and without fluid suppression by inversion recovery), and two double inversion recovery (DIR) proton MRI. DIR MRIs were used to create masks of gray and white matter (GM, WM), that were subsequently applied to the C1 and α maps calculated from sodium MRI and a tissue three-compartment model, in order to measure the distributions of these two parameters in GM, WM or full brain (GM+WM) separately. The mean, median, mode, standard deviation (std), skewness and kurtosis of the C1 and α distributions in whole GM, WM and full brain were calculated for each subject, averaged over all data, and used as parameters for the repeatability assessment. The coefficient of variation (CV) was calculated as a measure of reliability for the detection of intra-subject changes in C1 and αfor each parameter, while intraclass correlation (ICC) was used as a measure of repeatability. It was found that the CV of most of the parameters was around 10–20% (except for C1 kurtosis which is about 40%) for C1 and α measurements, and that ICC was moderate to very good (0.4 to 0.9) for C1 parameters and for some of the α parameters (mainly skewness and kurtosis). In conclusion, the proposed method could allow to reliably detect changes of 50% and above of the different measurement parameters of C1 and αin neuropathologies (multiple sclerosis, tumor, stroke, Alzheimer’s disease) compared to healthy subjects, and that skewness and kurtosis of the distributions of C1 and αseem to be the more sensitive parameters to these changes.
机译:这项研究的目的是评估在3 T时使用钠磁共振(MRI)在体内估计的假性细胞内钠浓度(C1)和假性细胞外体积分数(α)定量的可重复性。十一名健康受试者扫描两次,两次钠MRI采集(有和没有通过反转恢复抑制液体)和两次双反转恢复(DIR)质子MRI。 DIR MRI用于创建灰色和白色物质蒙版(GM,WM),然后将其应用于从钠MRI和组织三室模型计算出的C1和α图,以测量这两个参数的分布分别在GM,WM或全脑(GM + WM)中使用。计算每个受试者在整个GM,WM和全脑中的C1和α分布的平均值,中位数,众数,众数,标准偏差(std),偏度和峰度,对所有数据取平均值,并将其用作可重复性评估的参数。计算变异系数(CV)作为检测每个参数的受试者内部C1和α变化的可靠性的量度,而使用组内相关性(ICC)作为可重复性的量度。发现对于C1和α测量,大多数参数的CV约为10–20%(C1峰度除外,约为40%),并且对于C1参数,ICC中等至非常好(0.4到0.9)对于某些α参数(主要是偏度和峰度)。总之,与健康受试者相比,所提出的方法可以可靠地检测出神经病理学(多发性硬化,肿瘤,中风,阿尔茨海默氏病)中C1和α的不同测量参数变化的50%及以上,以及该变化的偏度和峰度C1和α的分布似乎是对这些变化更敏感的参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号