The aim of the study is to examine the validity in predicting body fat percentage (%BF) of different bioelectrical impedance (BIA) devices among Chinese children and adolescents. A total of 255 Chinese children and adolescents aged 9–19 years old participated in the study. %BF was assessed by BIA scales, namely, Biodynamics-310 (Model A), Tanita TBF-543 (Model B), Tanita BC-545 (Model C), and InBody 520 (Model D). Dual-energy X-ray absorptiometry (DXA) was used as the criterion measurement. Lin's concordance correlation coefficients of estimated %BF between Model A, Model B, Model C, and DXA showed poor agreements for both genders. Moderate agreements for %BF were found between DXA and Model D measurements. In boys, differences in %BF were found between DXA and Model B and Model C. No significant %BF differences were found between Model A, Model D, and DXA. However, the two BIA analyzers showed a significant positive correlation between the bias and average %BF between BIA and DXA. In girls, differences in %BF were observed between Model B, Model C, Model D, and DXA. Model A and DXA showed no significant differences of %BF; however, the bias and the average %BF between the BIA and DXA had a significant positive correlation. Using embedded equations in BIA devices should be validated in assessing the %BF of Chinese children and adolescents.
机译:这项研究的目的是检验在预测中国儿童和青少年不同生物电阻抗(BIA)设备的体脂百分比(%BF)方面的有效性。共有255名9-19岁的中国儿童和青少年参加了这项研究。通过BIA量表评估%BF,即Biodynamics-310(模型A),Tanita TBF-543(模型B),Tanita BC-545(模型C)和InBody 520(模型D)。双能X射线吸收法(DXA)被用作标准测量。 Lin估计模型A,模型B,模型C和DXA之间的%BF一致性相关系数表明,这两种性别的一致性都较差。在DXA和D型测量之间发现了%BF的适度一致性。在男孩中,DXA与模型B和模型C之间的%BF有差异。模型A,模型D和DXA之间没有发现显着的%BF差异。但是,这两个BIA分析仪在BIA和DXA之间的偏差与平均%BF之间显示出显着的正相关。在女孩中,在模型B,模型C,模型D和DXA之间观察到%BF的差异。模型A和DXA的%BF无明显差异;但是,BIA和DXA之间的偏差和平均%BF具有显着的正相关。在评估中国儿童和青少年的%BF时,应验证在BIA设备中使用嵌入式方程。

著录项

  • 期刊名称 other
  • 作者单位
  • 年(卷),期 -1(2015),-1
  • 年度 -1
  • 页码 614858
  • 总页数 8
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号