首页> 美国卫生研究院文献>other >EFFECTS OF THE GENIUM KNEE SYSTEM ON FUNCTIONAL LEVEL STAIR AMBULATION PERCEPTIVE AND ECONOMIC OUTCOMES IN TRANSFEMORAL AMPUTEES
【2h】

EFFECTS OF THE GENIUM KNEE SYSTEM ON FUNCTIONAL LEVEL STAIR AMBULATION PERCEPTIVE AND ECONOMIC OUTCOMES IN TRANSFEMORAL AMPUTEES

机译:膝关节锻炼系统对经络截肢者功能水平楼梯步态知觉和经济成果的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Compared to non-microprocessor knees, the C-Leg microprocessor knee (MPK) is bioenergentically and economically more efficient and safer for transfemoral amputation (TFA) patients. The Genium MPK has demonstrated improvements in perceived function, knee kinematics, and physical functional performance compared to C-Leg. Clinical and health economic analyses have not been conducted with the Genium knee system. The purpose of this study was to determine if laboratory determined benefits of Genium are detectable using common clinical assessments and if there are economic benefits associated with its use. This study utilized a randomized AB crossover study with 60 d follow-up including cost-effectiveness analysis. Twenty TFA patients tested with both knees in mobility and preference measures. Incremental cost-effectiveness ratios (ICER) were calculated based on performance measures. Stair Assessment Index scores improved with Genium. Mean stair completion times and descent stepping rate were not different between knees. Stair ascent stepping rate for C-Leg was greater compared with Genium (p = 0.04). Genium use decreased Four square step test completion time and increased functional level and step activity (p ≤ 0.05). Further, Genium use improved (p ≤ 0.05) function and safety in three out of five Activities of Daily Living (ADL) survey domains. Finally, more subjects preferred Genium following testing. Functional measures were used to calculate ICERs. ICER values for Genium fall within established likely-to-accept value ranges. Compared with C-Leg, Genium use improved stair walking performance, multi-directional stepping, functional level, and perceived function. In this group of community ambulators with TFA, Genium was preferred, and, while more costly, it may be worth funding due to significant improvements in functional performance with ADLs.
机译:与非微处理器膝盖相比,C腿微处理器膝盖(MPK)在经股动脉截肢(TFA)患者方面在生物能和经济上更加有效和安全。与C腿相比,Genium MPK已证明在感知功能,膝盖运动学和身体功能方面有所改善。 Genium膝关节系统尚未进行临床和健康经济分析。这项研究的目的是确定使用普通的临床评估方法是否可以检测到实验室确定的Genium益处,以及与使用Genium有关的经济利益。这项研究采用了随机AB交叉研究,并进行了60天的随访,包括成本效益分析。 20名TFA患者同时进行了膝关节活动度和偏爱度测试。基于绩效指标计算了增量成本效益比(ICER)。 Genium改善了楼梯评估指数得分。膝盖之间的平均楼梯完成时间和下降步速没有差异。与Genium相比,C腿的楼梯上升步幅更大(p = 0.04)。使用Genium减少了四平方步测试完成时间,并增加了功能水平和步阶活动(p≤0.05)。此外,在五种“日常生活活动”(ADL)调查领域中,有三项使用Genium改善了(p≤0.05)的功能和安全性。最后,更多受试者在测试后更喜欢Genium。功能度量用于计算ICER。 Genium的ICER值落入已建立的可能接受的值范围内。与C-Leg相比,Genium使用了改进的楼梯行走性能,多方向踏步,功能水平和可感知的功能。在这组使用TFA的社区步行者中,Genium是首选,尽管成本更高,但由于ADL的功能性能有了显着改善,因此可能值得投资。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号