摘要

>Background: The metered-dose inhalers (MDIs) currently available for inhaled corticosteroid delivery do not offer an integrated dose counter; therefore, it is difficult to evaluate adherence of patients. The present authors developed a linear regression equation using canister weight to calculate the number of doses actuated from the MDIs. This study aimed to assess medical adherence after the integration of regular weighing of the canisters into the routine service.  >Methods: A cohort study was carried out between May 2013 and April 2014. Children aged less than 8 years with a diagnosis of asthma were recruited. The duration of adherence assessment was 24 weeks. Participants had a regular schedule every 8 weeks to obtain a new FLIXOTIDE® 125 inhaler. Parents were asked to collect the discarded MDI canisters, which were then weighed by a laboratory scale. The weight of each canister was replaced in the regression equation to calculate the number of doses actuated from the MDIs.  >Results: A total of 52 asthmatic children participated in the study. The median age was 52.7 months. At the end of 24 weeks, 44, 33, and 23 discarded MDI canisters were collected from visits 1, 2, and 3, respectively. The median percentages of adherence were 96.8%, 96.3%, and 96.3%, respectively. In 11 discarded canisters (11%), the remaining medication was more than 30% of the labeled doses. Approximately 90% of the participants had no asthma exacerbation during 24-week study period.  >Conclusion: High adherence rates were achieved after integration of canister weighing into the asthma care service.
机译:>背景:目前可用于吸入皮质类固醇递送的计量吸入器(MDI)没有提供集成的剂量计数器;因此,很难评估患者的依从性。本文作者开发了一个线性回归方程,使用罐的重量来计算从MDI启动的剂量数。这项研究旨在评估将常规称重的滤罐纳入常规服务后的医疗依从性。 >方法:在2013年5月至2014年4月之间进行了一项队列研究。该研究招募了年龄在8岁以下且患有哮喘的儿童。依从性评估的持续时间为24周。参与者每8周定期安排一次新的FLIXOTIDE®125吸入器的使用。要求父母收集丢弃的MDI罐,然后用实验室秤称重。在回归方程式中替换每个罐的重量,以计算从MDI启动的剂量数。 >结果:共有52名哮喘儿童参加了这项研究。中位年龄为52.7个月。在24周结束时,分别从访问1、2和3收集了44、33和23个废弃的MDI罐。依从性的中位数百分比分别为96.8%,96.3%和96.3%。在11个废弃的罐中(占11%),剩余药物超过标记剂量的30%。在24周的研究期内,约90%的受试者没有哮喘发作。 >结论:将碳罐称重整合到哮喘护理服务中后,达到了较高的依从性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号