首页> 美国卫生研究院文献>other >An Automated Sample Preparation Instrument to Accelerate Positive Blood Cultures Microbial Identification by MALDI-TOF Mass Spectrometry (Vitek®MS)
【2h】

An Automated Sample Preparation Instrument to Accelerate Positive Blood Cultures Microbial Identification by MALDI-TOF Mass Spectrometry (Vitek®MS)

机译:一种自动样品制备仪器可通过MALDI-TOF质谱(Vitek®MS)加速血液阳性菌的微生物鉴定

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Sepsis is the leading cause of death among patients in intensive care units (ICUs) requiring an early diagnosis to introduce efficient therapeutic intervention. Rapid identification (ID) of a causative pathogen is key to guide directed antimicrobial selection and was recently shown to reduce hospitalization length in ICUs. Direct processing of positive blood cultures by MALDI-TOF MS technology is one of the several currently available tools used to generate rapid microbial ID. However, all recently published protocols are still manual and time consuming, requiring dedicated technician availability and specific strategies for batch processing. We present here a new prototype instrument for automated preparation of Vitek®MS slides directly from positive blood culture broth based on an “all-in-one” extraction strip. This bench top instrument was evaluated on 111 and 22 organisms processed using artificially inoculated blood culture bottles in the BacT/ALERT® 3D (SA/SN blood culture bottles) or the BacT/ALERT VirtuoTM system (FA/FN Plus bottles), respectively. Overall, this new preparation station provided reliable and accurate Vitek MS species-level identification of 87% (Gram-negative bacteria = 85%, Gram-positive bacteria = 88%, and yeast = 100%) when used with BacT/ALERT® 3D and of 84% (Gram-negative bacteria = 86%, Gram-positive bacteria = 86%, and yeast = 75%) with Virtuo® instruments, respectively. The prototype was then evaluated in a clinical microbiology laboratory on 102 clinical blood culture bottles and compared to routine laboratory ID procedures. Overall, the correlation of ID on monomicrobial bottles was 83% (Gram-negative bacteria = 89%, Gram-positive bacteria = 79%, and yeast = 78%), demonstrating roughly equivalent performance between manual and automatized extraction methods. This prototype instrument exhibited a high level of performance regardless of bottle type or BacT/ALERT system. Furthermore, blood culture workflow could potentially be improved by converting direct ID of positive blood cultures from a batch-based to real-time and “on-demand” process.
机译:脓毒症是重症监护病房(ICU)患者的主要死亡原因,需要早期诊断以引入有效的治疗干预。对致病性病原体的快速识别(ID)是指导定向抗菌药物选择的关键,最近被证明可以减少ICU的住院时间。 MALDI-TOF MS技术直接处理阳性血液培养物是目前可用于生成快速微生物鉴定的几种工具之一。但是,所有最近发布的协议仍然是手动且耗时的,需要专门的技术人员可用性和用于批处理的特定策略。我们在此展示一种新的原型仪器,该仪器可基于“多合一”提取条直接从阳性血液培养液中直接自动制备Vitek ® MS载玻片。使用BacT / ALERT ® 3D(SA / SN血液培养瓶)或BacT / ALERT Virtuo TM人工接种的血液培养瓶对处理的111种和22种生物进行了评估。 系统(FA / FN Plus瓶)。总体而言,当与BacT / ALERT一起使用时,这个新的准备站可对87%(革兰氏阴性细菌= 85%,革兰氏阳性细菌= 88%,酵母= 100%)进行可靠,准确的Vitek MS物种级鉴定。 >® 3D和Virtuo ®仪器分别占84%(革兰氏阴性菌= 86%,革兰氏阳性菌= 86%和酵母菌= 75%)。然后在临床微生物学实验室对102个临床血液培养瓶进行原型评估,并与常规实验室ID程序进行比较。总体而言,单菌瓶上ID的相关性为83%(革兰氏阴性菌= 89%,革兰氏阳性菌= 79%,酵母菌= 78%),表明手动和自动提取方法的性能大致相当。不论瓶子类型或BacT / ALERT系统如何,该原型仪器均具有很高的性能。此外,通过将阳性血液培养的直接ID从基于批次的过程转换为实时和“按需”过程,可以潜在地改善血液培养的工作流程。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号