To develop the point-of-care testing method to facilitate the clinical detection of severe fever with thrombocytopenia syndrome virus (SFTSV), colloidal gold paper-based lateral flow immunochromatography test strips (LFITSs) have been fabricated for the rapid detection for the first time. The pH value and the amount of monoclonal antibody to prepare colloidal gold nanoparticle-labeled monoclonal antibody bioconjugates were optimized. In addition, 0.4% bovine serum albumin was considered to be the best concentration for blocking nitrocellulose membranes. Under optimal conditions, the limit of detection for SFTSV was as low as 1 ng/mL depending on a visual line. Meanwhile, the entire detection process required no more than 10 min with a volume of only 50 μL of the analyte solution. Moreover, paper-based LFITSs were evaluated in real samples of human serum of patients with satisfactory results. In addition, all strips were of high stability and specificity. In the light of advantages such as simple, portable, rapid, and low cost, the developed LFITSs will extensively come into service, especiallyin remote areas.
机译:为了开发现场检查方法以便利临床检测血小板减少综合征病毒(SFTSV)的重度发热,首次制作了基于胶体金纸的侧向流免疫层析试纸(LFITSs),用于快速检测。优化了制备胶体金纳米颗粒标记的单克隆抗体生物偶联物的pH值和单克隆抗体的量。此外,认为0.4%的牛血清白蛋白是阻断硝酸纤维素膜的最佳浓度。在最佳条件下,视视线的不同,SFTSV的检出限低至1 ng / mL。同时,整个检测过程只需要50μL的分析物溶液就可以用不超过10分钟。此外,在患者的人血清的真实样品中评估了纸质LFITS,结果令人满意。另外,所有条带都具有高稳定性和特异性。鉴于简单,便携式,快速和低成本等优点,已开发的LFITS将广泛投入使用,尤其是在偏远地区。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号