Intensity-modulated radiotherapy and volumetric modulated arc therapy are modern radiation therapy technologies that can create the desired dose distribution by multileaf collimator movement and dose-rate control. However, the homogeneous dose delivery of small-field irradiation techniques shows disagreement with that of treatment planning system. The removal of the flattening filter by flattening filter free (FFF) beam irradiation increases dose conformity and further reduces treatment delivery time in radiosurgery. This study aims to investigate the dose distribution of FFF and flattened beams for small-field irradiation by using the 3D gel dosimeter. The N-isopropylacrylamide (NIPAM) polymer gel dosimeter was employed to record the 3D dose distribution. In addition, flattened and FFF beams were compared using the gamma evaluation technique. The use of an FFF accelerator resulted in excellent radiation treatments with short delivery times and low doses to normal tissues and organs. Results also showed that the passing rate increased with the decrease of field size (30 × 30, 20 × 20, and 10 × 10 mm2) at post-irradiation times of 24, 48, 72, and 96 h. The passing rates for each field size were retained at the same level when gamma criteria, namely, distance-to-agreement (DTA) = 3 mm/dose difference (DD) = 3%, were used. Nevertheless, the passing rates for each field size decreased slowly after 48 h when DTA = 2 mm/DD = 2%. The Wilcoxon signed-rank test was used to determine statistical difference with a significant level of p < 0.05. The passing rates of flattened and FFF beams showed no significant difference. The edge enhancement effect in the flattened beam was more evident than in the FFF beam. The 3D NIPAM gel dosimeter can be used for dose verification of small field for radiation therapy with high dose rate.
机译:强度调制放射疗法和体积调制电弧疗法是现代放射疗法技术,可以通过多叶准直仪的移动和剂量率控制来产生所需的剂量分布。然而,小剂量照射技术的均匀剂量输送显示出与治疗计划系统的不同。通过使无滤光片(FFF)光束辐射变平而去除变平滤光片,可以提高剂量一致性,并进一步减少放射外科手术中的治疗时间。这项研究旨在通过使用3D凝胶剂量计研究FFF和扁平光束在小视野照射下的剂量分布。 N-异丙基丙烯酰胺(NIPAM)聚合物凝胶剂量计用于记录3D剂量分布。此外,使用伽马评估技术比较了平坦光束和FFF光束。 FFF促进剂的使用可实现出色的放射治疗,且交货时间短且对正常组织和器官的剂量低。结果还表明,在照射后24、48、72和30的照射时间,通过率随视野尺寸(30×30、20×20和10×10 mm 2 )的减小而增加。 96小时当使用伽玛标准,即一致同意距离(DTA)= 3毫米/剂量差(DD)= 3%时,每个字段大小的通过率保持在相同水平。然而,当DTA = 2 mm / DD = 2%时,在48 h后每种视野大小的通过率均缓慢降低。 Wilcoxon秩和检验用于确定统计学差异,其显着水平为p <0.05。扁平光束和FFF光束的通过率没有显着差异。平坦光束的边缘增强效果比FFF光束更明显。 3D NIPAM凝胶剂量计可用于高剂量率放射治疗小视野的剂量验证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号