A pilot study of minimum operational flow for loose-fitting powered air-purifying respirators used in healthcare cleaning services

机译:卫生清洁服务中使用的松散式电动空气净化呼吸器的最低运行流量的初步研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The objective of this pilot study was to determine the minimum operational flow for loose-fitting powered air-purifying respirators (PAPR) used in healthcare cleaning services. An innovative respiratory flow recording device was worn by nine healthcare workers to obtain the minute volume (MV, L/min), mean inhalation flow (MIF, L/min), and peak inhalation flow (PIF, L/min) while performing “isolation unit work” (cleaning and disinfecting) of a patient room within 30 min. The MV and PIF were compared with the theoretical values obtained from an empirical formula. The correlations of MV, MIF, and PIF with subjects’ age, weight, height, body surface area (ADu), and body mass index (BMI) were analyzed. The average MV, MIF, and PIF were 33, 74, and 107 L/min, with maximal airflow rates of 41, 97, and 145 L/min, respectively, which are all below the current 170 L/min minimum operational flow for NIOSH certified loose-fitting PAPRs.
机译:这项初步研究的目的是确定医疗清洁服务中使用的松散式电动空气净化呼吸器(PAPR)的最小运行流量。九名医护人员佩戴了一种创新的呼吸流量记录设备,以在执行以下操作时获得分钟体积(MV,L / min),平均吸气流量(MIF,L / min)和峰值吸气流量(PIF,L / min)。 30分钟内对病房进行“隔离单元工作”(清洁和消毒)。将MV和PIF与从经验公式获得的理论值进行比较。分析了MV,MIF和PIF与受试者的年龄,体重,身高,体表面积(ADu)和体重指数(BMI)的相关性。平均MV,MIF和PIF为33、74和107 L / min,最大气流速率分别为41、97和145 L / min,均低于当前170 L / min的最小运行流量。 NIOSH认证的宽松PAPR。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号